Skip to main content
Siemens 3RA2210-1EA15-2AP6 — Motor Starters

Siemens 3RA2210-1EA15-2AP6 SIRIUS Reversing Motor Starter

MPN3RA2210-1EA15-2AP6

Siemens SIRIUS 3RA2210-1EA15-2AP6 non-fused reversing motor starter, size S00, CLASS 10, 1.5 kW at 400 V AC-3, 690 V rated insulation, DIN rail or screw mount.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1EA15-2AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP62
Included circuit-breaker (type)3RV2011-1EA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2210-1EA15-2AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)2 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V3.95 A
Rated current at 600 V4 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2210-1EA15-2AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)2.8 ... 4 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2210-1EA15-2AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO0
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2210-1EA15-2AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width90 mm
Height170 mm
Depth97.1 mm

Environmental

3RA2210-1EA15-2AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

What this reversing starter delivers — and what it doesn't

The 3RA2210-1EA15-2AP6 is a SIRIUS non-fused reversing motor starter in size S00 — a self-contained assembly that combines a contactor pair, overload relay, and reversing interlock in one package. The 'non-fused' designation means it expects upstream short-circuit protection (a circuit breaker or fuse) — the starter itself provides only overload protection. Supplied with a 3RT2015-1AP62 contactor and 3RA1921-1DA00 link module, so it's a drop-in reversing pair, not something you wire up from loose parts.

Ratings that decide the fit

The 1.5 kW at 400 V rating is the AC-3 (motor switching) power; at 500 V it handles 2.2 kW, and at 600 V the current limit is 4 A. Coil voltage is 187–242 V at 50 Hz and 192–264 V at 60 Hz — a dual-frequency coil that covers the common 208–240 V control transformer range.

Panel space and mounting

Dimensions are 170 mm high, 90 mm wide, 97.1 mm deep — size S00 footprint. Snaps onto 35 mm DIN rail or screws to a backplate with the included push-in lug. Mounting position is vertical only; the clearance requirements are 20 mm upward, 10 mm downward, and 9 mm at the sides — tight enough for dense panel layouts.

Lifecycle and sourcing

Compliance documentation includes RoHS/REACH substance prohibition dated 03/01/2017. The degree of pollution is 3 (industrial environment with conductive pollution), so it's rated for use in control panels without additional conformal coating.

Frequently asked questions

What is the difference between this reversing starter and a standard non-reversing SIRIUS starter?

This 3RA2210-1EA15-2AP6 is a reversing starter — it contains two contactors with mechanical interlock to switch motor direction, plus the overload relay, all in one size S00 package. A non-reversing SIRIUS starter (like the 3RA2110 series) has a single contactor and is smaller. The reversing version takes the same panel footprint as two non-reversing starters stacked, but saves wiring time because the interlock and power bus are pre-wired.

MPN
3RA2210-1EA15-2AP6