Skip to main content
Siemens 3RA2210-1FH15-2AP0 — Motor Starters

Siemens 3RA2210-1FH15-2AP0 SIRIUS Reversing Starter

MPN3RA2210-1FH15-2AP0
Active

Siemens SIRIUS 3RA2210-1FH15-2AP0 reversing starter, Size S00, 5 A at 600 V, spring-loaded terminals, 60 mm busbar snap-on, Trip Class 10, 690 V rated insulation.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1FH15-2AP0 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-2AP02
Included circuit-breaker (type)3RV2011-1FA20
Included link module (type)3RA2911-2AA00

Ratings & Performance

3RA2210-1FH15-2AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)5 hp
Rated current at 480 V4.8 A
Rated current at 600 V5 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2210-1FH15-2AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)3.5 ... 5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2210-1FH15-2AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2210-1FH15-2AP0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2210-1FH15-2AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height260 mm
Depth155 mm

Environmental

3RA2210-1FH15-2AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

What this reversing starter fits — and what it doesn't

The 3RA2210-1FH15-2AP0 is a SIRIUS reversing starter in Size S00, designed to snap onto 60 mm busbar systems — not a DIN rail mount, not a panel screw-down. If your panel is built around standard 35 mm DIN rail, this part needs an adapter or a different frame. It ships as a complete assembly: the supplied contactor is a 3RT2015-2AP02, and the link module is 3RA2911-2AA00. That means the reversing interlock and mechanical linkage are pre-configured — no separate wiring of a mechanical interlock between two contactors. The main circuit terminals are spring-loaded, not screw-clamp. That's fine for solid and ferruled stranded wire up to the rated cross-section, but if your shop standard is ring-tongue crimp lugs, you'll need to adapt or swap the terminal type.

Motor ratings — the numbers that decide the BOM line

For 230 V systems, it's 1.5 hp at 220/230 V or 0.5 hp at 230 V rated value — the lower horsepower at 230 V reflects the current-limited design of the S00 frame. That's standard for general-purpose motor starting — not for high-inertia loads that need a Class 20 or 30 curve. The operating temperature range is -20 to +60 °C, and the storage range is -50 to +80 °C — typical for a panel-mounted device in a conditioned enclosure.

Mounting clearances — where it sits in the enclosure

Physical dimensions are 155 mm deep, 90 mm wide, and 260 mm tall. Mounting is vertical only, and the clearance requirements are: 50 mm upwards, 32 mm forwards, 10 mm downwards, 10 mm at the side, and 0 mm backwards (it sits flush against the busbar). That 50 mm upward gap is the one that catches people — if you stack a busbar-fed starter below another device, you need that clearance for heat dissipation and wiring access.

Frequently asked questions

Will 3RA2210-1FH15-2AP0 drop into a panel specified around 6ES7517-3FP00-0AB0?

No. The 6ES7517-3FP00-0AB0 is a Siemens S7-1500 CPU module, not a motor starter. The 3RA2210-1FH15-2AP0 is a reversing starter that snaps onto 60 mm busbars — entirely different form factor, wiring, and function. Rewiring and a panel layout change are required.

MPN
3RA2210-1FH15-2AP0