Skip to main content
Siemens 3RA2210-1FS15-2BB4 — Motor Starters

Siemens 3RA2210-1FS15-2BB4 Reversing Starter, S00

MPN3RA2210-1FS15-2BB4
Active

Siemens SIRIUS 3RA2210-1FS15-2BB4 reversing starter, size S00, 1.5 kW at 400 V AC-3, Class 10 thermal overload, spring-loaded terminals, for 60 mm busbar systems.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1FS15-2BB4 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2015-2BB42
Included circuit-breaker (type)3RV2011-1FA20
Included link module (type)3RA2911-2AA00

Ratings & Performance

3RA2210-1FS15-2BB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4.8 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2210-1FS15-2BB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)3.5 ... 5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2210-1FS15-2BB4 — Contacts & Control
ParameterValue
Rated value24 ... 24 V
Control supply voltage typeDC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2210-1FS15-2BB4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2210-1FS15-2BB4 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height212 mm
Depth155 mm

Environmental

3RA2210-1FS15-2BB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

S00 reversing starter for 60 mm busbar systems

The 3RA2210-1FS15-2BB4 is a SIRIUS reversing starter in size S00, combining a 3RT2015-2BB42 contactor, a thermal bimetallic overload relay, and a 3RA2911-2AA00 link module in one assembly that snaps directly onto 60 mm busbar systems.

Trip class and overload protection

The thermal bimetallic element is temperature-compensated across the -20 to +60 °C operating range, so the trip point stays stable whether the panel is in a conditioned room or a hot plant floor.

Mounting and panel fit

Snaps onto 60 mm busbar systems using the supplied 8US1251-5DS11 busbar adapter — no DIN rail required, which saves a rail and frees up space in a crowded panel. Dimensions are 155 mm deep, 90 mm wide, 212 mm tall, with 50 mm clearance needed above and 32 mm in front; zero clearance behind, 10 mm at the sides and 10 mm below. Mounting position is vertical only — horizontal mounting is not supported, so plan the busbar orientation accordingly.

Wiring and termination

Main current circuit uses spring-loaded terminals — no screw torque to verify, no thermal cycling loosening, and faster wiring on a line swap. Rated for 50/60 Hz supply; the coil voltage is 24 V AC/DC, which is common across most PLC output cards and control transformers.

Environmental and compliance

Operates from -20 to +60 °C; stores and transports from -50 to +80 °C — fine for unheated warehouses or truck shipments in winter. RoHS compliance date is October 1, 2009, so it meets the EU substance restrictions for current installations.

Frequently asked questions

What motor power does 3RA2210-1FS15-2BB4 handle at 400 V?

It also covers 1 hp at 200/208 V and 220/230 V, and 3 hp at 460/480 V and 575/600 V.

Does 3RA2210-1FS15-2BB4 mount on a DIN rail or busbar?

It snaps onto 60 mm busbar systems using the supplied 8US1251-5DS11 busbar adapter — not a standard DIN rail. The mounting position must be vertical.

What type of overload protection does this reversing starter use?

A thermal bimetallic overload relay with Class 10 trip characteristic, temperature-compensated from -20 to +60 °C.

What are the wiring terminals on 3RA2210-1FS15-2BB4?

Spring-loaded terminals on the main current circuit — no screw terminals, so wiring is faster and more vibration-resistant.

MPN