Skip to main content
Siemens 3RA2210-1GA15-2AP6 — Motor Starters

Siemens 3RA2210-1GA15-2AP6 SIRIUS Reversing Motor Starter

MPN3RA2210-1GA15-2AP6

Siemens SIRIUS 3RA2210-1GA15-2AP6 reversing motor starter, size S00, Class 10 trip class, 690 V AC-3 rated voltage, snap-on DIN rail mount, 170 x 90 x 97.1 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1GA15-2AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AP62
Included circuit-breaker (type)3RV2011-1GA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2210-1GA15-2AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V2 200 W
Operational current Ie, AC-3 at 400 V4.9 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)5 hp
Rated current at 480 V4.8 A
Rated current at 600 V6.1 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000

Protection & Tripping

3RA2210-1GA15-2AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)4.5 ... 6.3 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2210-1GA15-2AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz187 ... 242 V
Auxiliary contacts, NO0
Auxiliary contacts, NC1
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2210-1GA15-2AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
Mounting positionvertical
Width90 mm
Height170 mm
Depth97.1 mm

Environmental

3RA2210-1GA15-2AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Reversing starter, S00 frame, Class 10 — what ships in the box

The 3RA2210-1GA15-2AP6 is a SIRIUS non-fused reversing motor starter in size S00, meaning it combines two contactors with a mechanical interlock and a thermal overload relay in one assembly for forward/reverse control of a three-phase motor. It ships with a 3RT2015-1AP62 contactor and a 3RA1921-1DA00 link module already integrated — the kit is complete for a reversing start function; no separate interlock or wiring of a reversing pair is needed.

Motor power coverage and voltage assignments

At 400 V AC-3, the starter is rated for 2 200 W (approx. 3 hp) motor output; at 480 V it handles 4.8 A, and at 600 V it handles 6.1 A — the current ceiling rises with voltage, so confirm the motor FLA against the applicable line voltage row. The AC-3 rated voltage maximum is 690 V, so the starter can be used on 400 V, 480 V, 600 V, and 690 V line-to-line systems without derating the switching capacity.

Mounting and panel fit — DIN rail or screw-mount

Envelope dimensions: 170 mm height, 90 mm width, 97.1 mm depth — the width is the same as a standard S00 contactor, so it fits in a 90 mm-wide DIN-rail slot with the reversing pair stacked vertically. Clearance requirements: 20 mm above, 10 mm below, 9 mm to the side, 0 mm forward and backward — plan the enclosure depth and wireway spacing accordingly, especially if mounting multiple starters in a row.

Environmental limits and compliance

Operating temperature range is -20 to +60 °C; storage range is -50 to +80 °C; transport range is -55 to +80 °C — the starter can be stored in unconditioned warehouses but must be within the operating band when powered. Degree of pollution 3 means it is rated for conductive pollution environments (typical in industrial control panels without climate control) — no additional conformal coating is required for normal factory-floor conditions. Substance prohibitance date is 03/01/2017 — the product complies with RoHS and REACH substance restrictions as of that date; current compliance documentation is available on request.

Frequently asked questions

Can 3RA2210-1GA15-2AP6 replace a 6ES7214-1BG40-0XB0 in a panel?

No — the 6ES7214-1BG40-0XB0 is a Siemens S7-1200 PLC CPU, not a motor starter. The 3RA2210 is a reversing motor starter for motor control; it cannot substitute a PLC and would require complete rewiring and a different panel layout.

What compliance documentation is available for 3RA2210-1GA15-2AP6?

The product has a substance prohibitance date of 03/01/2017, indicating RoHS/REACH compliance. Full declarations, UL/CSA/CE certificates, and the IEC 60947-4-1 test report are available from Siemens or through the distributor upon request.

MPN