What this reversing starter ships with
The 3RA2210-1GH15-2AP0: This SIRIUS reversing starter comes as a pre-assembled unit: a 3RT2015-2AP02 contactor, a 3RA2911-2AA00 link module, and an 8US1251-5DT11 busbar adapter, all on a size S00 frame. This saves time on a panel build where you're wiring multiple starters.
Snap-on busbar mounting saves DIN rail space
This starter is designed to snap directly onto 60 mm busbar systems — no separate DIN rail adapter needed. The fastening method is built into the S00 frame. Mounting position is vertical only. Clearance around the unit: 50 mm upward, 32 mm forward, 10 mm downward, 10 mm at the side, and 0 mm backward — the back face sits flush against the busbar. Dimensions are 260 mm high by 90 mm wide by 155 mm deep — check your enclosure depth before committing, especially if the busbar is near the back wall.
Active production, quoted per BOM
Operating temperature range is -20 to +60 °C, storage and transport -50 to +80 °C. The temperature-compensated overload release stays accurate across the operating band. Substance prohibitance date is 10/01/2009 — the unit complies with RoHS and REACH requirements for that cutoff.