Skip to main content
Siemens 3RA2210-1HD16-2BB4 — Motor Starters

Siemens 3RA2210-1HD16-2BB4 SIRIUS Reversing Starter

MPN3RA2210-1HD16-2BB4

Siemens SIRIUS reversing starter, size S00, 6.5 A AC-3 at 400 V, 24 V DC coil, Class 10, screw terminals, for 60 mm busbar systems.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1HD16-2BB4 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2016-1BB42
Included circuit-breaker (type)3RV2011-1HA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2210-1HD16-2BB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V3 000 W
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)5 hp
Rated motor power at 575/600 V (hp)5 hp
Rated current at 480 V8 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2210-1HD16-2BB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)5.5 ... 8 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2210-1HD16-2BB4 — Contacts & Control
ParameterValue
Rated value24 ... 24 V
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Mechanical & Connection

3RA2210-1HD16-2BB4 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height200 mm
Depth156 mm

Environmental

3RA2210-1HD16-2BB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

SIRIUS S00 reversing starter — 6.5 A AC-3 at 400 V

The 3RA2210-1HD16-2BB4: The 24 V DC coil holds at 4 W, so the control transformer and wiring need only that holding power once picked.

Supplied components — contactor, circuit-breaker, link module

The reversing starter ships as a factory-coordinated set: the supplied contactor is 3RT2016-1BB42, the supplied circuit-breaker is 3RV2011-1HA10, and the link module is 3RA1921-1DA00. This means the short-circuit protection and overload coordination are already matched — no separate selectivity calculation needed between the contactor and the breaker, provided the downstream motor full-load current falls within the breaker's setting range.

Mounting — snaps onto 60 mm busbar systems

The fastening method is for snapping onto 60 mm busbar systems — the design of the product is specifically for 60 mm busbars, so it mounts directly without an adapter plate. The mounting position is vertical; the dimensions are 156 mm deep, 90 mm wide, and 200 mm high, with clearances of 50 mm upwards, 32 mm forwards, 10 mm downwards, and 10 mm at the side. Backwards clearance is 0 mm, meaning it can sit flush against a back panel. Operating temperature range is -20 to +60 °C; storage and transport range is -50 to +80 °C.

The RoHS substance prohibitance date is 10/01/2009, so the part is RoHS-compliant for current builds.

Frequently asked questions

What is the 3RA2210-1HD16-2BB4 rated for in AC-3 duty?

This corresponds to a 3 kW motor at 400 V or a 5 hp motor at 460/480 V.

Does the 3RA2210-1HD16-2BB4 include the contactor and circuit-breaker?

Yes, it ships as a factory-coordinated set including the 3RT2016-1BB42 contactor, the 3RV2011-1HA10 circuit-breaker, and the 3RA1921-1DA00 link module. The overload release is thermal bimetallic, Trip Class 10.

MPN
3RA2210-1HD16-2BB4