Skip to main content
Siemens 3RA2210-1KD17-2BB4 — Motor Starters

Siemens 3RA2210-1KD17-2BB4 Reversing Starter, S00, 12 A AC-3

MPN3RA2210-1KD17-2BB4
Active

Siemens SIRIUS reversing starter, size S00, 12 A at 400 V AC-3, Class 10 trip, for snapping onto 60 mm busbar systems, supplied with 3RT2017-1BB42 contactor and 3RA1921-1DA00 link module.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2210-1KD17-2BB4 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS00
Included contactor (type)3RT2017-1BB42
Included circuit-breaker (type)3RV2011-1KA10
Included link module (type)3RA1921-1DA00

Ratings & Performance

3RA2210-1KD17-2BB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V5 500 kW
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)7.5 hp
Rated motor power at 575/600 V (hp)10 hp
Rated current at 480 V11 A
Rated current at 600 V11 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Protection & Tripping

3RA2210-1KD17-2BB4 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)9 ... 12.5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)1

Contacts & Control

3RA2210-1KD17-2BB4 — Contacts & Control
ParameterValue
Rated value24 ... 24 V
Control supply voltage typeDC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2210-1KD17-2BB4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2210-1KD17-2BB4 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height204 mm
Depth155 mm

Environmental

3RA2210-1KD17-2BB4 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

12 A AC-3 reversing starter on 60 mm busbars

The 3RA2210-1KD17-2BB4: Designed for snapping onto 60 mm busbar systems — the mounting footprint is vertical only, with 155 mm depth, 90 mm width, and 204 mm height.

Supplied components and wiring terminals

This reversing starter ships with the 3RT2017-1BB42 contactor and the 3RA1921-1DA00 link module — the contactor is pre-wired to the reversing interlock, so field wiring is limited to the main circuit and control voltage. Main current circuit connections use screw-type terminals, which are standard for panel builds and accept up to the wire sizes matching the S00 frame rating. The control supply is rated 24 V DC, with the coil draw determined by the 3RT2017 contactor — confirm the PLC output or relay can sink the inrush before committing the BOM.

Clearance and ambient limits

Minimum clearances around the unit: 50 mm upwards, 32 mm forwards, 10 mm downwards, and 10 mm at the side — no clearance needed at the back since it mounts directly on the busbar. Operating ambient temperature range is -20 to +60 °C, with storage and transport limits from -50 to +80 °C — the temperature compensation is active across the full operating band.

Frequently asked questions

What is the AC-3 current rating at 400 V for this reversing starter?

The maximum operating voltage for AC-3 duty is 690 V.

MPN
3RA2210-1KD17-2BB4