Skip to main content
Siemens 3RA2215-0BD15-2AK6 — Motor Starters

Siemens 3RA2215-0BD15-2AK6 SIRIUS Reversing Starter

MPN3RA2215-0BD15-2AK6

Siemens SIRIUS 3RA2215-0BD15-2AK6, non-fused reversing motor starter, Size S00, Trip Class 10, AC-3 rated 690 V, 50-60 Hz, thermal bimetallic overload, magnetic short-circuit trip.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RA2215-0BD15-2AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS00
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2015-1AK62
Included circuit-breaker (type)3RV2011-0BA15
Included link module (type)3RA1921-1DA00
3RA2215-0BD15-2AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V60 W
Operational current Ie, AC-3 at 400 V0.2 A
Rated voltage at AC-3, max.690 V
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)30 000 000
3RA2215-0BD15-2AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)0.14 ... 0.2 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2215-0BD15-2AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz93.5 ... 121 V
Auxiliary contacts, NO1
Auxiliary contacts, NC2
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2215-0BD15-2AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height200 mm
Depth155.1 mm
3RA2215-0BD15-2AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

The Siemens SIRIUS 3RA2215-0BD15-2AK6 is a non-fused reversing motor starter in Size S00, designed for direct-on-line reversing of three-phase motors up to 690 V AC-3 duty. The Trip Class 10 thermal bimetallic overload relay protects standard induction motors during start-up, while the magnetic short-circuit trip clears faults fast enough to avoid upstream breaker coordination issues.

The AC-3 rating at 690 V maximum means this starter switches squirrel-cage motors under full load — the standard duty for reversing applications on conveyors, pumps, and fans. The Trip Class 10 rating means it allows a 10-second overload before tripping, which covers most NEMA Design B and IEC standard motor starts without nuisance trips. The thermal bimetallic overload element tracks motor heating directly, so it responds to actual current, not just a simulated curve. The magnetic short-circuit trip provides instantaneous protection for the downstream motor and cable. Because it's a non-fused design, the upstream protective device (typically a circuit breaker or fuse) must be coordinated per the manufacturer's selectivity tables — the supplied circuit breaker 3RV2011-0BA15 is the intended match.

This reversing starter snaps onto standard 60 mm busbar systems, which is the common footprint for SIRIUS S00 feeders in motor control centers. The vertical mounting position is specified for proper heat dissipation from the bimetallic overload. The overall dimensions are 155.1 mm deep, 90 mm wide, and 200 mm high. The width is the critical dimension for DIN-rail or busbar spacing — at 90 mm, it occupies a standard 4-module width on a 60 mm busbar system. The depth of 155.1 mm means it will fit most standard 200 mm deep enclosures, but check the door clearance if a manual motor starter handle or operator is added. The supplied components include a contactor (3RT2015-1AK62), a link module (3RA1921-1DA00), a busbar adapter (8US1251-5DS10), and an RS assembly kit (3RA2913-1DB1). The main contact wiring accepts 0.5 to 4 mm² stranded or 2x (0.75 to 2.5 mm²), with AWG equivalents of 2x (20-16) for the contactor and 2x (18-14) or 2x 12 for the main circuit.

Frequently asked questions

Where can I buy 3RA2215-0BD15-2AK6?

This part is sourced to order against an RFQ through independent distribution. Availability and pricing are confirmed at quote time.

MPN
3RA2215-0BD15-2AK6