Skip to main content
Siemens 3RA2220-1JH24-0AP0 — Motor Starters

Siemens 3RA2220-1JH24-0AP0 SIRIUS Reversing Starter, S0

MPN3RA2220-1JH24-0AP0
Active

Siemens SIRIUS 3RA2220-1JH24-0AP0 reversing starter, Size S0, 4 kW at 400 V AC-3, Trip Class 10, spring-loaded terminals, 60 mm busbar snap-on.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2220-1JH24-0AP0 — Identification
ParameterValue
Product designationReversing starter
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructionfor 60 mm busbars
Circuit-breaker sizeS0
Included contactor (type)3RT2024-2AP00
Included circuit-breaker (type)3RV2021-1JA20
Included link module (type)3RA2921-2AA00

Ratings & Performance

3RA2220-1JH24-0AP0 — Ratings & Performance
ParameterValue
Rated motor power at 400 V4 000 W
Operational current Ie, AC-3 at 400 V8.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)5 hp
Rated motor power at 575/600 V (hp)7.5 hp
Rated current at 480 V7.6 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000

Protection & Tripping

3RA2220-1JH24-0AP0 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)150 000 A
Overload release setting range (current)7 ... 10 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2

Contacts & Control

3RA2220-1JH24-0AP0 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz230 ... 230 V
Control supply voltage typeAC
Auxiliary switch extensionYes
Switching contact typeelectromechanical

Communication

3RA2220-1JH24-0AP0 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2220-1JH24-0AP0 — Mechanical & Connection
ParameterValue
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height260 mm
Depth165 mm

Environmental

3RA2220-1JH24-0AP0 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-50 ... +80 °C
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

What this reversing starter delivers — and what it doesn't

The 3RA2220-1JH24-0AP0 is a SIRIUS reversing starter in Size S0 — meaning it packages two contactors and a thermal overload relay into one unit that swaps motor phase rotation for forward/reverse control. This is a hardwired reversing starter — no PROFIsafe or PROFINET IO onboard. It's designed for conventional control circuits where a PLC or relay logic toggles the direction contactors, not for networked safety drives. The supplied sub-assemblies are pre-integrated: a 3RT2024-2AP00 contactor, a 3RA2921-2AA00 link module, and an 8US1251-5NT11 busbar adapter. No separate ordering for these components.

Motor power ratings across common voltages

At 400 V, the rated motor power is 4 kW. At 460/480 V, it's 5 hp. At 575/600 V, it's 7.5 hp. For 200/208 V, it's 2 hp, and at 220/230 V, it's 3 hp. The rated current at 480 V is 7.6 A. This is standard for general-purpose motor starting; Class 10 is faster than Class 20, so it protects motors with shorter locked-rotor withstand times. Rated insulation voltage is 690 V, and the maximum AC-3 operating voltage is also 690 V — the starter's internal clearances handle 690 V line-to-line without derating.

Panel layout and busbar snap-on

The envelope is 260 mm high, 90 mm wide, 165 mm deep. Mounting position is vertical only. Fastening is by snapping onto 60 mm busbar systems — no DIN rail adapter required, but the busbar pitch must match. Clearance spacings: 50 mm upwards, 32 mm forwards, 10 mm downwards, 10 mm at the side, 0 mm backwards. These are the minimum free air gaps for heat dissipation and arc flash containment — don't crowd the top or front. Main circuit wiring uses spring-loaded terminals — no screw torque to verify, just strip and push. This speeds panel wiring but requires a ferrule for stranded wire to prevent strand fanning.

Thermal limits and storage range

Operating ambient temperature range is -20 to +60 °C with temperature compensation active across that span. Storage and transport range is -50 to +80 °C — the starter can sit in an unheated warehouse through winter without damage. Substance prohibitance date 03/01/2017 aligns with RoHS compliance — no restricted substances above threshold for EU market placement.

MPN
3RA2220-1JH24-0AP0