MPN3RA2225-1AB23-0AK6

Siemens SIRIUS 3RA2 non-fused reversing motor starter, size S0, CLASS 10 thermal bimetallic overload, 690 V AC-3, snap-on 35 mm DIN rail, 120 mm depth, 90 mm width, 265 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2225-1AB23-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AK60
Included circuit-breaker (type)3RV2011-1AA15
Included link module (type)3RA2921-1AA00
3RA2225-1AB23-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V550 W
Operational current Ie, AC-3 at 400 V1.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)0.75 hp
Rated current at 480 V1.6 A
Rated current at 600 V1.3 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2225-1AB23-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.1 ... 1.6 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2225-1AB23-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO3
Auxiliary contacts, NC3
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2225-1AB23-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodsnap-on fastening on 35 mm standard rail
Mounting positionvertical
Width90 mm
Height265 mm
Depth120 mm
3RA2225-1AB23-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Reversing starter that fits a tight panel slot

The 3RA2225-1AB23-0AK6 is a SIRIUS 3RA2 non-fused reversing motor starter in size S0 — meaning the contactor, overload relay, and reversing interlock ship as a single DIN-rail unit, not a field-assembled stack. Snap-on mounting on 35 mm standard rail, vertical position only — the thermal bimetallic overload (CLASS 10 trip class) is calibrated for vertical orientation; laying it flat shifts the trip curve. Footprint is 120 mm deep by 90 mm wide by 265 mm tall — the S0 frame keeps the gland-plate fill factor manageable in a 600 mm wide enclosure. Rated 690 V insulation voltage, AC-3 switching duty up to 690 V — covers 400 V, 480 V, 575 V, and 600 V line supplies without derating the voltage class.

Power ratings across common line voltages

At 400 V the starter is rated 550 W; at 460/480 V it delivers 0.75 hp; at 575/600 V also 0.75 hp — the motor full-load current at 480 V is 1.6 A, at 600 V it is 1.3 A. At 690 V the rating climbs to 1 100 W — useful for 690 V mining or marine distribution where the step-down transformer is upstream of the MCC. The supplied contactor is 3RT2023-1AK60; the link module is 3RA2921-1AA00; the busbar adapter is 3RA2922-1AA00 — all three are included, so no separate ordering for the reversing interlock hardware.

Thermal environment and pollution class

Operating ambient range is -20 to +60 °C — the bimetallic overload compensates across this band, but above 40 °C the trip current setting should be derated per the IEC 60947-4-1 derating curve. Pollution degree 3 means the unit is rated for conductive contamination (condensation, light dust) typical of industrial control panels without a sealed enclosure — no conformal coating required for the internal clearances. Storage range -50 to +80 °C and transport range -55 to +80 °C — the starter can sit in an unheated warehouse or ship in a non-climate-controlled truck without damage.

Lifecycle and compliance — current production, RoHS dated

RoHS compliance date is 03/01/2017 — the substance prohibition per EU Directive 2011/65/EU is met; no REACH SVHC declaration is in this record, but the RoHS date covers the standard industrial exemption set. The supplied sub-assemblies (contactor, link module, busbar adapter) are all current-production SIRIUS catalog items — no orphaned parts inside the assembly.

Frequently asked questions

What is the CLASS 10 trip class mean for motor protection?

This protects standard induction motors during start-up without nuisance tripping on normal acceleration, but it is not suitable for high-inertia loads that need CLASS 20 or CLASS 30.

What compliance documentation does Siemens provide for this motor starter?

The RoHS compliance date is 03/01/2017, covering EU Directive 2011/65/EU. No UL/CSA listing is in this record, but the SIRIUS 3RA2 series typically carries cULus and CE marks — confirm the specific certification with the order code suffix.

Can the 3RA2225-1AB23-0AK6 replace a field-assembled contactor-plus-overload reversing starter?

Yes — this is a factory-integrated reversing starter that includes the contactor, thermal overload, link module, and busbar adapter in one DIN-rail package. It replaces a field-assembled stack of two contactors, a mechanical interlock, and a separate overload relay, saving panel space and wiring time.