Skip to main content
Siemens 3RA2225-1AD23-0AP6 — Motor Starters

Siemens 3RA2225-1AD23-0AP6 SIRIUS Reversing Starter, Size S0

MPN3RA2225-1AD23-0AP6

Siemens SIRIUS 3RA2225-1AD23-0AP6 non-fused reversing motor starter, size S0, CLASS 10 thermal bimetallic overload, 400 V rated 550 W, 690 V AC-3 max, snap-on 60 mm busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2225-1AD23-0AP6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2023-1AP60
Included circuit-breaker (type)3RV2011-1AA15
Included link module (type)3RA2921-1AA00
3RA2225-1AD23-0AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V550 W
Operational current Ie, AC-3 at 400 V1.5 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)0.75 hp
Rated motor power at 575/600 V (hp)0.75 hp
Rated current at 480 V1.6 A
Rated current at 600 V1.3 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2225-1AD23-0AP6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)1.1 ... 1.6 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2225-1AD23-0AP6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz176 ... 242 V
Auxiliary contacts, NO3
Auxiliary contacts, NC3
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2225-1AD23-0AP6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodfor snapping onto 60 mm busbar systems
Mounting positionvertical
Width90 mm
Height260 mm
Depth155 mm
3RA2225-1AD23-0AP6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Reversing starter built for busbar panels

The 3RA2225-1AD23-0AP6 is a SIRIUS non-fused reversing motor starter — size S0 load feeder, designed for snapping onto 60 mm busbar systems without additional mounting hardware. It ships as a complete assembly: a 3RT2023-1AP60 contactor, a 3RA2921-1AA00 link module, and an 8US1251-5NT10 busbar adapter. The thermal bimetallic overload release is set to CLASS 10 trip curve — standard for motor protection on general-purpose pumps, fans, and conveyors where the start-up transient clears within 10 seconds at locked-rotor current. Rated 550 W at 400 V and 1.6 A at 480 V, with a maximum AC-3 switching voltage of 690 V. The 50 Hz coil range is 176...242 V; 60 Hz range is 192...264 V — covers most global low-voltage motor control panels without a separate control transformer.

Panel fit and clearance envelope

Dimensions are 155 mm deep, 90 mm wide, 260 mm tall — the S0 frame keeps the footprint compact for multi-starter panels. Mounting position is vertical only; clearance requirements are 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards. Main contact wire range accepts 1...10 mm² stranded, or 2x (2.5...6 mm²) — enough for the rated current without oversized lugs. Degree of pollution 3 means it's rated for industrial environments with conductive dust or occasional condensation.

Lifecycle and procurement — active, quoted to order

The supplied contactor (3RT2023-1AP60), link module (3RA2921-1AA00), and busbar adapter (8US1251-5NT10) are all standard SIRIUS components, so field spares and replacements are straightforward to source separately if needed.

Frequently asked questions

What is the CLASS 10 trip curve mean for motor protection?

This suits standard induction motors with normal starting duty — pumps, fans, compressors — where the start current clears before the trip threshold. For high-inertia loads like centrifuges, a CLASS 20 or CLASS 30 curve would be needed.

What compliance documentation does Siemens provide for 3RA2225-1AD23-0AP6?

The SIRIUS 3RA2 series is designed to IEC/EN 60947-4-1 for motor starters and holds CE, UKCA, and cULus certifications for global panel acceptance.

MPN