Skip to main content
Siemens 3RA2225-1FB24-0AK6 — Motor Starters

Siemens 3RA2225-1FB24-0AK6 SIRIUS Reversing Starter

MPN3RA2225-1FB24-0AK6

Siemens SIRIUS 3RA2225-1FB24-0AK6 non-fused reversing motor starter, S0 size, Class 10, 4.8 A at 480 V, 3RT2024 contactor, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA2225-1FB24-0AK6 — Identification
ParameterValue
Product designationnon-fused motor starter 3RA2
Main circuit poles3
BrandSIRIUS
Load feeder sizeS0
Product design / constructionreversing starter
Circuit-breaker sizeS00
Included contactor (type)3RT2024-1AK60
Included circuit-breaker (type)3RV2011-1FA15
Included link module (type)3RA2921-1AA00
3RA2225-1FB24-0AK6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Operational current Ie, AC-3 at 400 V3.6 A
Rated voltage at AC-3, max.690 V
Rated motor power at 460/480 V (hp)3 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4.8 A
Rated current at 600 V4.55 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Rated insulation voltage Ui (AC, pollution degree 3)690 V
Mechanical service life, typ. (switching cycles)10 000 000
3RA2225-1FB24-0AK6 — Protection & Tripping
ParameterValue
Trip classCLASS 10
Short-circuit protectionYes
Rated short-circuit current at 400 V (IEC 60947-4-1)153 000 A
Overload release setting range (current)3.5 ... 5 A
Overload release typethermal (bimetallic)
Short-circuit trip typemagnetic
Duty / utilization type (IEC 60947-6-2)2
3RA2225-1FB24-0AK6 — Contacts & Control
ParameterValue
Rated value690 V
Rated voltage range at 50 Hz88 ... 121 V
Auxiliary contacts, NO3
Auxiliary contacts, NC3
Auxiliary switch extensionYes
Switching contact typeelectromechanical
3RA2225-1FB24-0AK6 — Mechanical & Connection
ParameterValue
Main circuit connection typescrew-type terminals
Main contact conductor range (AWG)2x (16 ... 12), 2x (14 ... 8)
Mounting / fastening methodsnap-on fastening on 35 mm standard rail
Mounting positionvertical
Width90 mm
Height265 mm
Depth120 mm
3RA2225-1FB24-0AK6 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-50 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)6g / 11 ms

Product details

Reversing starter in the SIRIUS S0 frame

The 3RA2225-1FB24-0AK6 is a non-fused reversing motor starter from the Siemens SIRIUS family, built in the S0 load feeder size. It combines a 3RT2024-1AK60 contactor with a link module 3RA2921-1AA00 and a circuit-breaker sized S00 — all pre-assembled and tested as a single unit. The 690 V maximum rated value (AC-3) covers 600 V class systems with headroom.

DIN rail integration and clearances

Snap-on fastening on 35 mm standard rail — no tools needed for mounting or removal. Mounting position is vertical only; the 265 mm height, 90 mm width, and 120 mm depth define the panel footprint. Clearance distances: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards. These are the minimum air gaps to maintain around the enclosure for heat dissipation and arc flash containment — plan the DIN rail layout accordingly. Main contact wire range is 1 to 10 mm² stranded, or 2× (2.5 to 6 mm²) for paralleling conductors. The S0 frame accepts the full range without adapters.

Environmental range and compliance

Operating temperature -20 to +60 °C, storage -50 to +80 °C, transport -55 to +80 °C. The -20 °C floor matters for unheated plant areas; the +60 °C ceiling limits panel ambient before derating is needed. Degree of pollution 3 per IEC 60947-1 — conductive pollution is expected (condensation, occasional dust), so the starter is suited for industrial environments without sealed enclosures.

Frequently asked questions

What are the key ratings for the 3RA2225-1FB24-0AK6 reversing starter?

It is a Class 10 reversing starter in the S0 frame, rated 4.8 A at 480 V and 4.55 A at 600 V, handling 3 hp at both 460/480 V and 575/600 V. Maximum rated voltage is 690 V AC-3.

What clearance distances are needed around the 3RA2225-1FB24-0AK6?

Minimum clearances: 30 mm upwards, 10 mm forwards, 10 mm downwards, 9 mm at the side, and 0 mm backwards. These are required for heat dissipation and arc flash containment.

MPN