Skip to main content
Siemens 3RA2316-8XB37-1DW4 — Motor Starters

Siemens 3RA2316-8XB37-1DW4 SIRIUS Reversing Contactor

MPN3RA2316-8XB37-1DW4

Siemens SIRIUS reversing contactor assembly, size S00, 3RA2316-8XB37-1DW4, rated 4 kW at 400 V AC-3, supplied with two 3RT2016-1DW47 contactors and integrated varistor surge suppression.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2316-8XB37-1DW4 — Identification
ParameterValue
Product designationReversing contactor assembly
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA2316-8XB37-1DW4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V4 kW
Rated motor power at 460/480 V (hp)5 hp
Rated motor power at 575/600 V (hp)7.5 hp
Rated current at 480 V7.6 A
Rated current at 600 V9 A

Contacts & Control

3RA2316-8XB37-1DW4 — Contacts & Control
ParameterValue
Control supply voltage typeDC
Auxiliary switch extensionYes

Communication

3RA2316-8XB37-1DW4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2316-8XB37-1DW4 — Mechanical & Connection
ParameterValue
Main contact conductor range (AWG)2x (20 ... 16), 2x (18 ... 14)
Mounting / fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width90 mm
Height68 mm
Depth145 mm

Environmental

3RA2316-8XB37-1DW4 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

What this assembly is

The Siemens 3RA2316-8XB37-1DW4 is a factory-assembled reversing contactor from the SIRIUS family, size S00. It ships as a complete unit with two 3RT2016-1DW47 contactors and a built-in varistor surge suppressor wired across the coil.

Motor ratings and duty

The AC-3 rating means it switches motors during starting and plugging — the contactors are sized for the inrush, not just the running current. At 480 V it is rated 7.6 A, at 600 V it carries 9 A, and at 690 V the motor power rating is 5.5 kW. Horsepower equivalents are 2 hp at 200/208 V, 3 hp at 220/230 V, 5 hp at 460/480 V, and 7.5 hp at 575/600 V.

The S00 footprint is compact: 90 mm wide, 68 mm tall, 145 mm deep. Clearance around the assembly is 6 mm upwards, forwards, downwards, and to the side; zero clearance needed backwards.

Wiring terminals

Main current circuit and coil connections use screw-type terminals. The terminal blocks accept solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm².

Frequently asked questions

Does 3RA2316-8XB37-1DW4 include auxiliary contacts and varistors?

Yes. It includes six instantaneous auxiliary contacts (three per direction) and a factory-fitted varistor surge suppressor across the coil.

Where can I buy 3RA2316-8XB37-1DW4?

This part is sourced to order against an RFQ. Submit a request for current pricing and availability; it is quoted through independent distribution channels.

MPN
3RA2316-8XB37-1DW4