SIRIUS reversing contactor assembly — size S0, 15 kW at 400 V
The 3RA2327-8XB30-1AG2: The assembly includes one supplied contactor, model 3RT2027-1AG20, per direction of rotation.
Mounting, wiring, and environmental limits
Envelope dimensions are 101 mm height, 90 mm width, and 97 mm depth — measure the panel cutout before committing. Both main and coil terminations are screw-type terminals. The assembly withstands shock: 13.5 g / 5 ms and 8.3 g / 10 ms on AC, 15 g / 5 ms and 10 g / 10 ms on DC. Clearance distances for ventilation and arc: 6 mm upwards, 6 mm forwards, 0 mm backwards, 6 mm downwards, 6 mm at the side.
Duty ratings and mechanical endurance
Maximum switching frequency in AC-3 and AC-3e duty is 750 operations per hour. Mechanical life of the contactor is typical 10,000,000 operations. The assembly includes 2 instantaneous auxiliary contacts. These matter when sizing upstream contactors or calculating total harmonic draw in a multi-motor panel.