3RA2416-8XF31-2AP6 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q
3RA2416-8XF31-2AP6 — Ratings & Performance
ParameterValue
Rated motor power at 400 V7.5 kW
Rated voltage at AC-3, max.690 V
3RA2416-8XF31-2AP6 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz220 V
Control supply voltage typeAC
Auxiliary switch extensionNo
3RA2416-8XF31-2AP6 — Communication
ParameterValue
AS-Interface protocol supportNo
3RA2416-8XF31-2AP6 — Mechanical & Connection
ParameterValue
Main contact conductor range (AWG)1x (20 ... 12)
Mounting / fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width135 mm
Height84 mm
Depth145 mm
3RA2416-8XF31-2AP6 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

Star-delta starter assembly — what ships in the box

This 3RA2416-8XF31-2AP6 is a pre-assembled SIRIUS contactor assembly for star-delta (wye-delta) starting of three-phase motors. It ships with three contactors: two 3RT2017-2AP61 and one 3RT2015-2AP61, plus the RS assembly kit 3RA2913-2BB2. Maximum AC-3 operating voltage is 690 V.

DIN rail fit and panel clearance

The S00 frame measures 84 mm high, 135 mm wide, and 145 mm deep — that depth includes the spring-loaded terminals, so plan for wire bend radius behind the rail. Clearance requirements: 6 mm upwards, forwards, downwards, and to the sides; 0 mm backwards (the back of the assembly sits flush against the mounting surface).

Terminations and wiring

All main circuit, auxiliary, and control circuit connections use spring-loaded terminals — no screw torquing needed, but the cage mechanism demands a solid or ferruled stranded conductor. The magnet coil also terminates on spring-type terminals. For AWG, main contacts accept 1x (20... 12). The spring clamp holds the full cross-section without cold flow — wire the ferrule fully seated before closing the lever.

Duty cycle and mechanical endurance

Maximum switching rate in AC-3 duty is 1 000 operations per hour. Typical mechanical life of the contactor is 10 000 000 cycles — this is the no-load mechanical endurance; electrical life under load will be lower and depends on the motor current and switching frequency. Shock resistance: 10.5 g for 5 ms and 6.6 g for 10 ms, tested at both AC and DC.