Siemens 3RA2417-8XE31-1BB4 — Motor Starters

Siemens 3RA2417-8XE31-1BB4 SIRIUS Star-Delta Starter, 11 kW

MPN3RA2417-8XE31-1BB4
NRND

Siemens SIRIUS 3RA2417-8XE31-1BB4 contactor assembly for star-delta (wye-delta) start, size S00, 11 kW at 400 V, screw-type terminals, 3x supplied contactors.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2417-8XE31-1BB4 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA2417-8XE31-1BB4 — Ratings & Performance
ParameterValue
Rated motor power at 400 V11 kW

Contacts & Control

3RA2417-8XE31-1BB4 — Contacts & Control
ParameterValue
Control supply voltage typeDC
Auxiliary switch extensionNo

Communication

3RA2417-8XE31-1BB4 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2417-8XE31-1BB4 — Mechanical & Connection
ParameterValue
Main contact conductor range (AWG)2x (20 ... 16), 2x (18 ... 14)
Mounting / fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width135 mm
Height68 mm
Depth145 mm

Environmental

3RA2417-8XE31-1BB4 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

Star-delta starter, pre-assembled

The Siemens 3RA2417-8XE31-1BB4 is a SIRIUS contactor assembly purpose-built for star-delta (wye-delta) motor starting. It ships as a complete unit with three contactors already mounted and wired: two 3RT2018-1BB41-0CC0 (or 3RT2018-1BB41) for the line and delta legs, and one 3RT2016-1BB41 for the star leg.

Mounting and wiring constraints

Clearance requirements: 6 mm upwards, forwards, downwards, and to the side; zero clearance needed backwards. The envelope is 68 mm high, 135 mm wide, and 145 mm deep — compact for a three-contactor assembly in size S00. All terminals — main, auxiliary, and control — are screw-type. For AWG, that's 2x (20...16) or 2x (18...14).

Fuse coordination and compliance

With assignment type 2 coordination, the required upstream fuses are gG NH 3NA, DIAZED 5SB, or NEOZED 5SE, all rated 25 A. This ensures the starter survives a short-circuit without damage to the contactors. Substance prohibited date is 10/01/2009 — the assembly complies with RoHS and REACH substance restrictions as of that date.

Frequently asked questions

Where can I buy 3RA2417-8XE31-1BB4 and get a price?

This part is available to order.

MPN
3RA2417-8XE31-1BB4