Skip to main content
Siemens 3RA2423-8XF32-1AL2 — Motor Starters

Siemens 3RA2423-8XF32-1AL2 SIRIUS Star-Delta Contactor

MPN3RA2423-8XF32-1AL2
Active

Siemens SIRIUS 3RA2423-8XF32-1AL2, star-delta (wye-delta) contactor assembly, Size S0, 11 kW at 400 V AC-3, screw terminals, 3 x 3RT2024-1AL20 contactors supplied.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2423-8XF32-1AL2 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q
3RA2423-8XF32-1AL2 — Ratings & Performance
ParameterValue
Rated motor power at 400 V11 kW
Rated voltage at AC-3, max.690 V
3RA2423-8XF32-1AL2 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz230 V
Control supply voltage typeAC
Auxiliary switch extensionNo
3RA2423-8XF32-1AL2 — Communication
ParameterValue
AS-Interface protocol supportNo
3RA2423-8XF32-1AL2 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width135 mm
Height101 mm
Depth171 mm
3RA2423-8XF32-1AL2 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

The Siemens SIRIUS 3RA2423-8XF32-1AL2 is a factory-assembled star-delta (wye-delta) contactor assembly for motor starting. It comes with three 3RT2024-1AL20 contactors and a mechanical interlock RS assembly kit 3RA2923-2BB1, all pre-mounted on a common base plate. This is a bolt-on solution for reducing inrush current on three-phase induction motors during start-up, switching the windings from star to delta once the motor reaches speed. Rated for AC-3 duty up to 690 V, the assembly delivers 11 kW at 400 V, 15.6 kW at 500 V, and 19 kW at 690 V. The AC-3 rating means it's designed for starting squirrel-cage motors and switching them off while running — the standard duty for contactors in motor control centers and panel builds.

Size S0 footprint — 101 mm high, 135 mm wide, 171 mm deep — fits standard panel layouts. Maintain the specified clearances: 6 mm upwards, forwards, downwards, and to the side; 0 mm backwards. Main circuit and control wiring terminate at screw-type terminals. Solid conductors: 2x (1... 2.5 mm²) and 2x (2.5... 10 mm²). Stranded: 2x (0.5... 1.5 mm²) and 2x (0.75... 2.5 mm²). The magnet coil also uses screw terminals.

Frequently asked questions

Is 3RA2423-8XF32-1AL2 suitable for wye-delta starting?

Yes, the product designation is 'contactor assembly for star-delta (wye-delta) start'. It includes three contactors and the mechanical interlock needed for the transition.

Where can I buy 3RA2423-8XF32-1AL2?

This part is sourced to order against an RFQ. Availability and pricing are confirmed at quote time.

MPN
3RA2423-8XF32-1AL2