Siemens 3RA2434-8XF32-1NB3 — Motor Starters

Siemens 3RA2434-8XF32-1NB3 SIRIUS Star-Delta Starter, 22 kW

MPN3RA2434-8XF32-1NB3
Active

Siemens SIRIUS 3RA2434-8XF32-1NB3 contactor assembly for star-delta (wye-delta) start, 22 kW at 400 V AC-3, Size S2, screw-type terminals, with varistor surge suppression.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2434-8XF32-1NB3 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA2434-8XF32-1NB3 — Ratings & Performance
ParameterValue
Rated motor power at 400 V22 kW
Rated voltage at AC-3, max.690 V

Contacts & Control

3RA2434-8XF32-1NB3 — Contacts & Control
ParameterValue
Control supply voltage typeAC/DC
Auxiliary switch extensionNo

Communication

3RA2434-8XF32-1NB3 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2434-8XF32-1NB3 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew fixing
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width177.5 mm
Height142 mm
Depth223 mm

Environmental

3RA2434-8XF32-1NB3 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

The 3RA2434-8XF32-1NB3: It ships with three contactors: two 3RT2035-1NB30 units for the line and star legs, and one 3RT2026-1NB30 for the delta leg. The assembly includes a varistor surge suppressor across the coil and an RS assembly kit (3RA2933-2C) for wiring the interlocking and timing circuits. The contactor size is S2, and the mechanical life is rated at 10 million operating cycles typical.

Mounting and wiring constraints

All terminals are screw-type — no spring-cage option on this variant.

Protection coordination and environmental limits

For Type 2 coordination, the required upstream fuse is 80 A gG (NH 3NA, DIAZED 5SB, or NEOZED 5SE).

Frequently asked questions

What contactors are supplied with 3RA2434-8XF32-1NB3?

The assembly includes two 3RT2035-1NB30 contactors (for line and star circuits) and one 3RT2026-1NB30 contactor (for the delta circuit). All are screw-type terminal versions.

What is the motor power rating of 3RA2434-8XF32-1NB3?

The maximum switching frequency is 1,000 operations per hour.

MPN
3RA2434-8XF32-1NB3