Siemens 3RA2436-8XF32-1NB3 — Motor Starters

Siemens 3RA2436-8XF32-1NB3 SIRIUS Star-Delta Starter, 45 kW

MPN3RA2436-8XF32-1NB3
Active

Siemens SIRIUS 3RA2436-8XF32-1NB3 star-delta contactor assembly, 45 kW at 400 V AC-3, S2 size, screw terminals, with varistor surge suppression.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2436-8XF32-1NB3 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA2436-8XF32-1NB3 — Ratings & Performance
ParameterValue
Rated motor power at 400 V45 kW
Rated voltage at AC-3, max.690 V

Contacts & Control

3RA2436-8XF32-1NB3 — Contacts & Control
ParameterValue
Control supply voltage typeAC/DC
Auxiliary switch extensionNo

Communication

3RA2436-8XF32-1NB3 — Communication
ParameterValue
AS-Interface protocol supportNo

Mechanical & Connection

3RA2436-8XF32-1NB3 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew fixing
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width177.5 mm
Height142 mm
Depth223 mm

Environmental

3RA2436-8XF32-1NB3 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

Star-delta starter that ships as a wired assembly

The 3RA2436-8XF32-1NB3: It arrives with three contactors already on a mounting plate: two 3RT2036-1NB30 units and one 3RT2028-1NB30, plus the RS assembly kit 3RA2933-2C and a varistor surge suppressor wired in. Rated 45 kW at 400 V AC-3, with a maximum AC-3 switching frequency of 800 operations per hour. That means it handles a 45 kW delta-wound motor through the start transition without the interlocking headaches of a field-built circuit.

What the S2 frame and 223 mm depth mean for your panel

The assembly uses the S2 contactor frame size — 142 mm high, 177.5 mm wide, and 223 mm deep. The depth is the dimension that catches people out on shallow backpanels; make sure your enclosure has at least 230 mm clear behind the gland plate. Mounting position is flexible: the assembly can be rotated ±180° on a vertical surface and tilted forward or backward ±22.5°, which helps when the cable entry is off-centre. Clearance around the unit: 10 mm upwards, forwards, downwards, and to the side; zero backwards clearance needed. The screw-fixing fastening method means you'll need M4 or M5 hardware through the mounting plate — no DIN-rail clip here.

Wiring terminals and conductor sizing

All terminals are screw-type — no push-in convenience here, so budget for a torque screwdriver on the BOM. The magnet coil operates on 20 to 33 V DC with a closing power of 28 W.

Lifecycle and sourcing — current production, no successor drama

That means it's still a standard BOM line for new panel builds, not a legacy scavenger hunt. The fuse assignment for type 2 coordination calls for gG NH 3NA, DIAZED 5SB, or NEOZED 5SE fuses rated at 80 A. Keep that on the fuse schedule when you order the panel hardware.

Frequently asked questions

What mechanical life can I expect from this star-delta starter?

Typical mechanical life is 10,000,000 operations.

Is the 3RA2436-8XF32-1NB3 RoHS compliant?

Yes, the substance prohibition date is 10/01/2014, which aligns with RoHS compliance.

MPN
3RA2436-8XF32-1NB3