Skip to main content
Siemens 3RA2445-8XF32-1AC2 — Motor Starters

Siemens 3RA2445-8XF32-1AC2 SIRIUS Star-Delta Starter

MPN3RA2445-8XF32-1AC2
Active

Siemens SIRIUS 3RA2445-8XF32-1AC2 star-delta contactor assembly, 75 kW at 400 V AC-3, 110 kW at 690 V, 3RT2045-1AC20 + 3RT2036-1AC20 contactors, screw terminals, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2445-8XF32-1AC2 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q
3RA2445-8XF32-1AC2 — Ratings & Performance
ParameterValue
Rated motor power at 400 V75 kW
Rated voltage at AC-3, max.690 V
3RA2445-8XF32-1AC2 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz24 V
Control supply voltage typeAC
Auxiliary switch extensionNo
3RA2445-8XF32-1AC2 — Communication
ParameterValue
AS-Interface protocol supportNo
3RA2445-8XF32-1AC2 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width220 mm
Height180 mm
Depth244 mm
3RA2445-8XF32-1AC2 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

Star-delta contactor assembly, SIRIUS S3 frame

The 3RA2445-8XF32-1AC2: This is a pre-assembled star-delta (wye-delta) contactor set from the SIRIUS series, built around two 3RT2045-1AC20 contactors and one 3RT2036-1AC20 contactor, plus the RS assembly kit 3RA2943-2C. It's a single order code for the whole start circuit — no hunting for individual contactors and interlocking hardware. Rated 75 kW at 400 V and 110 kW at 690 V in AC-3 duty, so it handles the transition from star to delta for a motor up to that power — the 690 V rating matters if you're running a 575 V or 690 V line in a North American or mining installation. Dimensions are 220 mm wide by 180 mm tall by 244 mm deep — confirm the enclosure backplane fits before wiring.

Sourcing and lifecycle — active, quoted to order

Sourced through authorized distribution channels; quantities quoted against your BOM at RFQ. For fuse protection, the assembly requires 160 A gG NH 3NA, DIAZED 5SB, or NEOZED 5SE fuses when using type 2 coordination. Get the fuse spec right on the BOM — mismatched fuses break coordination and you'll lose the starter in a fault.

Environmental and mounting tolerances

Vibration resistance is 10.6 g at 5 ms and 6.3 g at 10 ms — this holds up on a machine frame or conveyor drive base, not just a quiet control panel.

Frequently asked questions

What contactors are supplied with this star-delta assembly?

The assembly ships with two 3RT2045-1AC20 contactors and one 3RT2036-1AC20 contactor, plus the RS assembly kit 3RA2943-2C.

MPN