Siemens 3RA2446-8XH32-1NB3 — Motor Starters

Siemens 3RA2446-8XH32-1NB3 SIRIUS Star-Delta Starter

MPN3RA2446-8XH32-1NB3
NRND

Siemens SIRIUS 3RA2446-8XH32-1NB3 star-delta contactor assembly, Size S3, 90 kW at 400 V AC-3, 132 kW at 690 V AC-3, screw-type terminals, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2446-8XH32-1NB3 — Identification
ParameterValue
Product designationContactor assembly for star-delta (wye-delta) start
Main circuit poles3
BrandSIRIUS
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA2446-8XH32-1NB3 — Ratings & Performance
ParameterValue
Rated motor power at 400 V90 kW
Rated voltage at AC-3, max.690 V

Contacts & Control

3RA2446-8XH32-1NB3 — Contacts & Control
ParameterValue
Control supply voltage typeAC/DC
Auxiliary switch extensionNo

Communication

3RA2446-8XH32-1NB3 — Communication
ParameterValue
AS-Interface protocol supportYes

Mechanical & Connection

3RA2446-8XH32-1NB3 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Width220 mm
Height180 mm
Depth244 mm

Environmental

3RA2446-8XH32-1NB3 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C

Product details

The 3RA2446-8XH32-1NB3 is a pre-assembled SIRIUS star-delta (wye-delta) contactor assembly from Siemens, Size S3, designed to reduce inrush current during motor start by connecting the windings in star, then switching to delta for run. It ships with three contactors already matched: two 3RT2046-1NB30 (one with surge suppressor 3RT2046-1NB30-0CC0) and one 3RT2037-1NB30, plus the RS assembly kit 3RA2943-2C — no separate ordering or coordination needed. Rated 90 kW at 400 V AC-3 and 132 kW at 690 V AC-3, with a maximum AC-3 switching voltage of 690 V. The mechanical life of the contactor typical is 10 million operations.

Dimensions: 220 mm wide, 180 mm high, 244 mm deep. The depth is the critical dimension for enclosure depth clearance — 244 mm means it will not fit a shallow 200 mm enclosure without a door offset. The 60 °C ceiling is standard for industrial panels without active cooling; above that, derating applies.

Wiring and protection requirements

Main current circuit and auxiliary/control circuit both use screw-type terminals. The coil connection also uses screw terminals. For Type 2 coordination (no damage to the contactor under short circuit), the required upstream fuse is 160 A — gG NH 3NA, DIAZED 5SB, or NEOZED 5SE. This is the fuse the panel builder needs on the BOM. The surge suppressor is built in with a varistor design — no external RC snubber needed for coil suppression on DC control.

Sourcing and lifecycle — current production, quoted to order

Sourced through authorized distribution channels. No stock-holding claim — each order is confirmed individually. RoHS compliance date is 03/01/2017 — the assembly meets the EU RoHS substance restrictions as of that date.

Frequently asked questions

What is the maximum switching rate for this star-delta starter?

The maximum switching rate at AC-3 duty is 850 operations per hour. This is the thermal limit of the contactor assembly under motor starting conditions.

What fuse rating is required for Type 2 coordination?

For Type 2 coordination, the required upstream fuse is 160 A, available as gG NH 3NA, DIAZED 5SB, or NEOZED 5SE types.

MPN
3RA2446-8XH32-1NB3