Siemens 3RA2832-2DG10 — Motor Starters

Siemens 3RA2832-2DG10 SIRIUS Function Module

MPN3RA2832-2DG10
Active

Siemens SIRIUS 3RA2832-2DG10 function module, OFF-delay, adjustable time 0.05-100 s, AC/DC 24-90 V, clip-on DIN rail, 74 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA2832-2DG10 — Identification
ParameterValue
Product designationfunction module
BrandSIRIUS
Reference designation (IEC 81346-2)K
3RA2832-2DG10 — Ratings & Performance
ParameterValue
Rated impulse withstand voltage (Uimp)4 kV
3RA2832-2DG10 — Contacts & Control
ParameterValue
Control supply voltage typeAC/DC
3RA2832-2DG10 — Mechanical & Connection
ParameterValue
Mounting / fastening methodclip-on
Mounting positionany (like contactor)
Width45 mm
Height38 mm
Depth74 mm
3RA2832-2DG10 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-40 ... +85 °C
Transport temperature range-40 ... +85 °C
Pollution degree3
Shock resistance (IEC 60068-2-27)15g / 11 ms

Product details

OFF-delay timing for sequenced motor stops

The 3RA2832-2DG10 is a SIRIUS function module that provides an adjustable OFF-delay from 0.05 to 100 s, triggered by the contactor's auxiliary contact opening. This lets you sequence downstream equipment shutdown — a pump discharge valve closing before the motor stops, or a conveyor section coasting to clear product before the brake engages. It operates on AC or DC control voltage from 24 to 90 V at 50/60 Hz, so it works across common control transformer taps and 24 VDC PLC outputs without a separate power supply module.

DIN-rail footprint and panel fit

Clips onto the DIN rail alongside the SIRIUS contactor — 45 mm wide, 74 mm deep, 38 mm tall. The 0 mm clearance on all sides (up, down, forward, backward) means you can pack modules tight in the enclosure without worrying about heat dissipation or arc flash clearance. Operating temperature range -25 to +60 °C covers unventilated cabinets on the plant floor; storage range -40 to +85 °C handles warehouse extremes.

Wiring and termination details

The recovery time after a timing cycle is 50 ms — fast enough for repeated start-stop sequences on indexing conveyors. The module provides delayed switching with OFF-delay only (no ON-delay, no pulse-shaping). Minimum ON period is 35 ms, so the contactor must stay closed at least that long for the OFF-delay to arm properly.

Frequently asked questions

What is the adjustable time range on 3RA2832-2DG10?

The OFF-delay is adjustable from 0.05 to 100 seconds, set via a potentiometer on the module face.

MPN
3RA2832-2DG10