Skip to main content
Siemens 3RA2913-3K — Motor Starters

Siemens 3RA2913-3K 3-phase infeed terminals, 22 A, S00

MPN3RA2913-3K
Active

Siemens SIRIUS 3RA2913-3K 3-phase infeed terminals, 22 A, S00 size, screw-type box terminals, for 3RT201 contactors, 28.4 mm depth, 25.9 mm width, 30.4 mm height.

$6.58Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA2913-3K — Identification
ParameterValue
Product designation3-phase infeed terminals
BrandSIRIUS

Ratings & Performance

3RA2913-3K — Ratings & Performance
ParameterValue
Rated insulation voltage Ui (AC, pollution degree 3)690 V

Mechanical & Connection

3RA2913-3K — Mechanical & Connection
ParameterValue
Main contact conductor range (AWG)1x (12 ... 8)
Width25.9 mm
Height30.4 mm
Depth28.4 mm

Environmental

3RA2913-3K — Environmental
ParameterValue
Operating temperature range-40 ... +60 °C
Storage temperature range-50 ... +80 °C

Product details

What this infeed terminal does in a SIRIUS starter assembly

The Siemens 3RA2913-3K is a 3-phase infeed terminal block from the SIRIUS family, designed to feed line power into a contactor assembly — specifically the 3RT201 series, size S00. Rated for 22 A maximum ampacity and 690 V insulation voltage at pollution degree 3, it handles the main circuit feed for motor starter combinations up to that current ceiling.

Panel fit — the 28.4 mm depth matters for DIN-rail clearance

At 28.4 mm deep, 25.9 mm wide, and 30.4 mm tall, this terminal block is compact enough to sit flush against the contactor without protruding past the DIN rail envelope — important when the panel backplate is tight against the enclosure door. The S00 contactor size is the smallest Siemens SIRIUS frame, so the infeed terminal matches that footprint — no wasted rail space in a multi-starter lineup.

Wire termination — what the conductor ranges actually cover

Solid wire acceptance is 1x (2.5 to 6.0 mm²) — a single conductor per clamp, not parallel feeds. Stranded wire range is 2.5 to 6 mm², and finely stranded with ferrule goes up to 10 mm². AWG equivalents for the main contacts are 12 to 8 AWG — common for 22 A motor branch circuits on 480 V or 400 V systems.

Environmental limits and compliance

Operating temperature range is -40 to +60 °C, storage range is -50 to +80 °C — suitable for unheated control cabinets in temperate or cold climates. Substance prohibitance date of 10/01/2009 aligns with RoHS compliance — the terminal meets the EU substance restrictions for industrial equipment.

Frequently asked questions

What is 3RA2913-3K's listed depth?

The depth is 28.4 mm, with a width of 25.9 mm and height of 30.4 mm — compact enough for tight DIN-rail layouts.

What wire sizes does 3RA2913-3K accept?

Solid wire: 1x (2.5 to 6.0 mm²). Stranded: 2.5 to 6 mm². Finely stranded with ferrule: up to 10 mm². AWG equivalent for main contacts: 12 to 8 AWG.

MPN
3RA2913-3K