Skip to main content
Siemens 3RA6120-0EB30 — Motor Starters

Siemens 3RA6120-0EB30 SIRIUS Compact Starter, 24 V DC, 53 kA

MPN3RA6120-0EB30
Active

Siemens SIRIUS 3RA6120-0EB30 compact starter, direct starter design, 24 V DC/AC control voltage, 53 kA breaking capacity at 400 V, adjustable trip Class 10 and 20, screw and snap-on mounting on DIN rail.

$397.51Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RA6120-0EB30 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q
3RA6120-0EB30 — Ratings & Performance
ParameterValue
Rated motor power at 400 V15 000 W
Rated motor power at 460/480 V (hp)20 hp
Rated current at 480 V32 A
Rated impulse withstand voltage (Uimp)6 000 V
3RA6120-0EB30 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)8 ... 32 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2
3RA6120-0EB30 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz24 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
3RA6120-0EB30 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width45 mm
Height170 mm
Depth165 mm
3RA6120-0EB30 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

Compact starter with adjustable trip class

The Siemens 3RA6120-0EB30 is a SIRIUS compact starter — a direct starter that integrates the contactor and overload relay into a single 45 mm-wide housing, saving panel space compared to a two-device combination. The overload trip class is field-adjustable between Class 10 and Class 20, letting you match the thermal protection to the motor start profile — Class 10 for fast-starting loads like pumps, Class 20 for high-inertia loads such as conveyors or fans.

Control voltage and mounting flexibility

The coil accepts both AC and DC at 24 V (24... 24 V DC, 24 V at 50/60 Hz), simplifying wiring in mixed-voltage control panels — one part covers both supply types. Mounts vertically or horizontally on standard DIN rail via screw and snap-on fastening; the 45 x 170 x 165 mm (W x H x D) footprint fits standard 45 mm-wide DIN-rail slots, and the any-position mounting orientation eases layout in tight enclosures. The main circuit connects via plug-in terminals without screw clamps — the plug-in design speeds replacement and reduces wiring errors during commissioning.

Frequently asked questions

What is the 3RA6120-0EB30 used for?

It is a SIRIUS compact starter — a direct motor starter combining a contactor and overload relay in one unit. It is used to start and protect three-phase motors in industrial control panels, with an adjustable trip class (Class 10 or 20) to match the motor's starting characteristics.

MPN
3RA6120-0EB30