Skip to main content
Siemens 3RA6120-1DP33 — Motor Starters

Siemens 3RA6120-1DP33 SIRIUS Compact Starter

MPN3RA6120-1DP33
Active

Siemens SIRIUS 3RA6120-1DP33 compact motor starter, direct starter design, 5.5 kW at 400 V, 53 kA interrupting capacity, adjustable Trip Class 10/20, 45 mm wide, screw and snap-on mounting.

$298.45Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA6120-1DP33 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q
3RA6120-1DP33 — Ratings & Performance
ParameterValue
Rated motor power at 400 V5 500 W
Rated motor power at 460/480 V (hp)7.5 hp
Rated motor power at 575/600 V (hp)10 hp
Rated current at 480 V12 A
Rated current at 600 V12 A
Rated impulse withstand voltage (Uimp)6 000 V
3RA6120-1DP33 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)3 ... 12 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2
3RA6120-1DP33 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz240 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes
3RA6120-1DP33 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width45 mm
Height170 mm
Depth165 mm
3RA6120-1DP33 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

Panel space and mounting — 45 mm wide, 165 mm deep

The 3RA6120-1DP33 occupies 45 mm width on standard DIN rail — three 9 mm module slots — with a depth of 165 mm and height of 170 mm. That depth matters when you're fitting it into a 200 mm deep enclosure; you've got 35 mm clearance behind the rail for wiring and the plug-in main circuit connector. Mounting position is unrestricted — vertical, horizontal, or any angle — and the screw-and-snap-on fastening means you can pre-wire the harness and snap the starter onto the rail without removing terminals.

Interrupting capacity and motor protection — 53 kA at 400 V

Rated 53 kA at 400 V, this starter handles high-fault panels without needing a separate upstream fuse or breaker for SCCR compliance. At 500 V it's still rated 3 kA, and at 690 V the same 3 kA — so it's usable on 400 V systems with high available fault current, but on 690 V systems you'll need to verify the fault level at the panel. The adjustable Trip Class (10 and 20) lets you match the thermal curve to the motor start profile — Class 10 for fast-starting pumps and fans, Class 20 for high-inertia loads like conveyors or centrifuges that need a longer acceleration ramp without nuisance tripping.

Motor power ratings across voltages

The 12 A continuous rating at 480/600 V means it's also a fit for 5 hp motors on 480 V North American systems.

Control voltage and coil consumption — universal AC/DC 110-240 V

That universal input simplifies panel wiring — one control transformer covers both the starter and the PLC power supply, and the low coil draw keeps the control transformer sizing modest.

Wiring terminals — solid and stranded capacity

Accepts solid wire 0.5-4 mm² (single) or 2x 0.5-2.5 mm² (two conductors per clamp). That's enough for 4 mm² supply tails on a 5.5 kW motor circuit, and the dual-conductor rating lets you daisy-chain the supply through multiple starters without extra terminal blocks.

Environmental ratings — industrial panel ready

Rated for continuous operation per IEC 60947-6-2, pollution degree 3, operating temperature -20 to +60 °C, and storage/transport -55 to +80 °C. Shock resistance 6g (10 ms, 3 shocks per axis) and vibration resistance to 20 m/s² at 5.8-500 Hz — it survives machine-mount vibration on conveyors and pumps without loosening.

Frequently asked questions

What is the interrupting capacity of 3RA6120-1DP33 at 400 V?

Rated 53 kA at 400 V. This means it's suitable for high-fault panels on 400 V systems but requires fault-level verification on higher voltage systems.

MPN
3RA6120-1DP33