Skip to main content
Siemens 3RA6120-2AB32 — Motor Starters

Siemens 3RA6120-2AB32 SIRIUS Compact Starter, 24 VDC, 53 kA

MPN3RA6120-2AB32
Active

Siemens SIRIUS 3RA6120-2AB32 compact starter, direct starter, 24 V DC/AC control, 53 kA breaking capacity at 400 V, adjustable trip class 10 and 20, spring-loaded terminals, 45 mm wide.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA6120-2AB32 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA6120-2AB32 — Ratings & Performance
ParameterValue
Rated motor power at 400 V90 W
Rated current at 480 V0.4 A
Rated current at 600 V0.4 A
Rated impulse withstand voltage (Uimp)6 000 V

Protection & Tripping

3RA6120-2AB32 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)0.1 ... 0.4 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2

Contacts & Control

3RA6120-2AB32 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz24 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes

Mechanical & Connection

3RA6120-2AB32 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width45 mm
Height191 mm
Depth165 mm

Environmental

3RA6120-2AB32 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

The Siemens 3RA6120-2AB32 is a SIRIUS compact starter — a direct-on-line motor starter that combines a contactor and overload relay in one 45 mm wide package. It's meant for continuous duty per IEC 60947-6-2, so it's sized for running a motor load, not just jogging it. The 24 V DC/AC control voltage means it drops into a standard 24 V control circuit without a separate transformer tap.

At 480 V the interrupting rating drops to 0.4 A, and at 690 V it's 3 kA, so match the rating to your available fault current. The adjustable trip class — selectable between CLASS 10 and CLASS 20 — lets you set the overload curve to the motor's thermal capacity: CLASS 10 for pumps and fans that start unloaded, CLASS 20 for high-inertia loads like centrifuges or crushers that need a longer acceleration ramp.

Frequently asked questions

What is the trip class of 3RA6120-2AB32?

It's adjustable between CLASS 10 and CLASS 20. CLASS 10 trips faster for standard-start loads; CLASS 20 gives more time for high-inertia starts. You set it with the dial on the overload block.

Where can I buy 3RA6120-2AB32 available via RFQ confirmation?

This part is sourced to order against your RFQ. Availability and pricing are confirmed at quote time.

MPN
3RA6120-2AB32