Siemens 3RA6120-2CB34 — Motor Starters

Siemens 3RA6120-2CB34 SIRIUS Compact Starter, 53 kA at 400 V

MPN3RA6120-2CB34
Active

Siemens SIRIUS 3RA6120-2CB34 compact motor starter, direct starter design, 53 kA at 400 V, adjustable trip class 10/20, 45 mm width, spring-loaded terminals, 24 V AC/DC coil.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA6120-2CB34 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA6120-2CB34 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Rated motor power at 460/480 V (hp)2 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4 A
Rated current at 600 V4 A
Rated impulse withstand voltage (Uimp)6 000 V

Protection & Tripping

3RA6120-2CB34 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)1 ... 4 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2

Contacts & Control

3RA6120-2CB34 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz24 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes

Mechanical & Connection

3RA6120-2CB34 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width45 mm
Height191 mm
Depth165 mm

Environmental

3RA6120-2CB34 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

SCCR and interrupting capacity — 53 kA at 400 V

The 3RA6120-2CB34 carries a short-circuit breaking capacity of 53 kA at 400 V. For a 400 V distribution system with a prospective fault current of, say, 25 kA, this starter holds the unit on the grid provided the upstream protective device is coordinated.

Trip class — adjustable CLASS 10 and 20

The overload relay is field-adjustable between CLASS 10 and CLASS 20. CLASS 20 allows up to 20 seconds, covering high-inertia loads like conveyors or crushers where the start transient lasts longer. The adjustment is a mechanical dial on the front face; no module swap needed.

DIN-rail footprint and wiring

Mounts on standard 35 mm DIN rail — 45 mm wide, 191 mm tall, 165 mm deep. Screw-and-snap-on fastening means you can pre-assemble the starter on a sub-panel and snap it onto the rail as a unit. The 24 V AC/DC coil is common across the SIRIUS family, so a shared control transformer feeds multiple starters without separate rectifiers.

Environmental and mechanical endurance

Rated for continuous operation per IEC 60947-6-2, pollution degree 3 — that is the industrial environment with conductive dust and condensation. Shock resistance 60 m/s² (6g) for 10 ms, three shocks per axis; vibration resistance per the spec: 4–5.8 Hz at 15 mm amplitude, 5.8–500 Hz at 20 m/s², 10 cycles. Operating temperature -20 to +60 °C, storage/transport -55 to +80 °C. Two status LEDs give local indication of coil energisation and overload trip.

Frequently asked questions

What is the interrupting capacity of 3RA6120-2CB34 at 400 V?

53 kA at 400 V. This is the short-circuit breaking capacity for the motor starter output — it must be coordinated with the upstream protective device to ensure the fault is cleared within the starter's rating.

MPN
3RA6120-2CB34