Skip to main content
Siemens 3RA6120-2CP33 — Motor Starters

Siemens 3RA6120-2CP33 SIRIUS Compact Starter, 53 kA at 400 V

MPN3RA6120-2CP33
Active

Siemens SIRIUS 3RA6120-2CP33 compact direct starter, 53 kA at 400 V, adjustable Class 10/20, 110-240 V AC/DC, 45 mm wide, screw and snap-on DIN rail.

$255.27Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RA6120-2CP33 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructiondirect starter
Reference designation (IEC 81346-2)Q

Ratings & Performance

3RA6120-2CP33 — Ratings & Performance
ParameterValue
Rated motor power at 400 V1 500 W
Rated motor power at 460/480 V (hp)2 hp
Rated motor power at 575/600 V (hp)3 hp
Rated current at 480 V4 A
Rated current at 600 V4 A
Rated impulse withstand voltage (Uimp)6 000 V

Protection & Tripping

3RA6120-2CP33 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)1 ... 4 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2

Contacts & Control

3RA6120-2CP33 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz240 V
Auxiliary contacts, NO1
Auxiliary contacts, NC1
Auxiliary switch extensionYes

Mechanical & Connection

3RA6120-2CP33 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width45 mm
Height191 mm
Depth165 mm

Environmental

3RA6120-2CP33 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

SIRIUS compact starter — 53 kA breaking capacity, adjustable trip class

The Siemens 3RA6120-2CP33 is a SIRIUS compact direct starter designed for continuous motor duty per IEC 60947-6-2. The adjustable trip class (Class 10 or 20) lets you match the overload protection to the motor start profile — Class 10 for fast-starting pumps and fans, Class 20 for high-inertia loads like conveyors or centrifuges. That flexibility is the main reason this starter replaces separate overload relay swaps in the panel.

Panel fit and wiring — 45 mm wide, 191 mm tall

At 45 mm wide, 191 mm tall, and 165 mm deep, this starter occupies a single 45 mm DIN rail slot — the same footprint as a standard contactor-plus-overload pair, but pre-integrated. The main circuit connects via plug-in terminals (no screw terminals on the power side), which speeds replacement: pull the old unit, snap in the new one, re-terminate the control wires. Solid wire capacity is 2x (0.25 to 1.5 mm²) on the control terminals. That's enough for standard 1.0 mm² or 1.5 mm² control wiring; if your panel uses 2.5 mm² for long runs, you'll need a ferrule or a terminal adapter. Mounting position is any orientation, though vertical on horizontal DIN rail is recommended. The shock rating of 60 m/s² (6g) for 10 ms across all axes and the vibration spec (15 mm displacement at 4–5.8 Hz, 20 m/s² acceleration at 5.8–500 Hz) mean it holds up in pump skids and conveyor sections without additional bracketing.

Control voltage and coil power — universal AC/DC, low standby draw

This simplifies stocking — one part number covers both 120 V and 240 V control systems common in North American and European panels. Coil power consumption is 6 W AC maximum and 5.1 W DC maximum. That's low enough to daisy-chain several starters on a single 24 VDC power supply without exceeding the supply's rating, though the coil is 110–240 V, not 24 V — plan your control transformer accordingly. Two onboard LEDs indicate coil status and trip condition — useful for quick fault isolation on the line without a meter.

Environmental range and compliance

Operating temperature spans -20 to +60 °C, storage and transport from -55 to +80 °C. Pollution degree 3 means it tolerates conductive dust and humidity typical of industrial enclosures without conformal coating.

Frequently asked questions

What is the breaking capacity of 3RA6120-2CP33 at 400 V?

53 kA at 400 V. That rating means it safely interrupts fault currents up to 53,000 A at 400 V without upstream fuses or a larger breaker — sufficient for most industrial panelboards fed from a 1,000 kVA transformer.

What motor power does 3RA6120-2CP33 handle at 400 V?

Rated for 1,500 W (2 hp) at 400 V in continuous duty. At 200/208 V it's rated 0.75 hp. The adjustable trip class (10 or 20) lets you tune the overload curve to the motor's starting characteristics.

MPN
3RA6120-2CP33