Siemens 3RA6250-2EB34 SIRIUS Reversing Starter, 15 kW, 53 kA

MPN3RA6250-2EB34
Active

Siemens SIRIUS compact reversing starter, order code 3RA6250-2EB34, 15 kW at 400 V, 53 kA breaking capacity, adjustable trip class 10/20, 24 V DC/AC control, spring-loaded terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RA6250-2EB34 — Identification
ParameterValue
Product designationcompact starter
Main circuit poles3
BrandSIRIUS
Product design / constructionreversing starter
Reference designation (IEC 81346-2)Q
3RA6250-2EB34 — Ratings & Performance
ParameterValue
Rated motor power at 400 V15 000 W
Rated motor power at 460/480 V (hp)20 hp
Rated current at 480 V32 A
Rated impulse withstand voltage (Uimp)6 000 V
3RA6250-2EB34 — Protection & Tripping
ParameterValue
Trip classCLASS 10 and 20 adjustable
Short-circuit protectionYes
Overload release setting range (current)8 ... 32 A
Duty / utilization type (IEC 60947-6-2)continous operation according to IEC 60947-6-2
3RA6250-2EB34 — Contacts & Control
ParameterValue
Rated voltage range at 50 Hz24 V
Auxiliary contacts, NO2
Auxiliary contacts, NC0
Auxiliary switch extensionYes
3RA6250-2EB34 — Mechanical & Connection
ParameterValue
Mounting / fastening methodscrew and snap-on mounting
Mounting positionany
Width90 mm
Height191 mm
Depth165 mm
3RA6250-2EB34 — Environmental
ParameterValue
Operating temperature range-20 ... +60 °C
Storage temperature range-55 ... +80 °C
Transport temperature range-55 ... +80 °C
Pollution degree3

Product details

The Siemens 3RA6250-2EB34 is a SIRIUS compact reversing starter rated for 15 kW at 400 V with a 53 kA breaking capacity at that voltage — enough to handle motor faults on a 400 V line without cascading upstream. The adjustable trip class (10 or 20) lets you match the overload curve to the motor's start profile: Class 10 for fast-starting pumps and fans, Class 20 for high-inertia loads like conveyors or crushers that need a longer acceleration window.

Control voltage and wiring

Control voltage is 24 V AC/DC — the coil accepts both, so you can land it on a 24 V DC PLC output or a 24 V AC control transformer without a separate rectifier.

Frequently asked questions

Can 3RA6250-2EB34 be used for 24 V DC control?

Yes, the control supply is rated 24 V AC/DC, so it works directly on a 24 V DC control circuit without an extra power supply or relay.

MPN