Siemens 3RA9012-5AS18 Reversing Contactor, 32 A, 24 VDC

MPN3RA9012-5AS18

Siemens 3RA9012-5AS18 reversing contactor, 3-pole, 32 A, 24 VDC coil, 1NO-3NC auxiliary contacts, integral S, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

32 A reversing contactor, 24 VDC coil — what it does in a panel

The 3RA9012-5AS18 is a Siemens reversing contactor, 3-pole, rated 32 A, with a 24 VDC coil. It includes 1NO-3NC auxiliary contacts per contactor, and the 'integral S' designation means the overload relay and contactor are factory-matched as a single assembly — no loose parts to wire up, no mis-match on the rail. This is a Motor Starters category part, so it's built for starting and reversing three-phase motors in control panels. The reversing configuration swaps two phases to reverse the motor direction — typical for conveyors, hoists, or any line that needs forward/reverse without a separate interlock relay.

Lifecycle and sourcing — active, quoted to order

No stock-holding claim — quoted per RFQ.

What the 32 A rating means for motor duty

32 A is the continuous thermal current (Ith) for a reversing contactor in this frame size — it's the current the main poles can carry without exceeding the temperature rise limit. For AC-3 motor switching (starting and stopping a squirrel-cage motor under load), a 32 A contactor typically handles a 15–18 kW motor at 400 V, but the exact motor FLC must be checked against the contactor's AC-3 rating in the Siemens selection table. The 24 VDC coil draws a holding current in the tens of milliamps once picked — the inrush is higher but brief. The 1NO-3NC aux contacts per contactor give you one normally-open and three normally-closed auxiliary poles for status feedback or interlocking, which is useful for reversing circuits where mechanical interlocks aren't enough.

Frequently asked questions

What does the 32 A rating mean for a reversing contactor?

32 A is the continuous current rating for the main poles. For AC-3 motor duty, this typically covers motors up to about 15–18 kW at 400 V, but confirm the exact motor FLC against the Siemens AC-3 rating table for this frame.

What are the auxiliary contacts on the 3RA9012-5AS18?

It has 1NO-3NC auxiliary contacts per contactor — one normally-open and three normally-closed poles. These are built into the reversing assembly, so no separate aux contact block is needed for basic status or interlock wiring.