Siemens 3RB2016-1SD0 — Overload Relays

Siemens 3RB2016-1SD0 SIRIUS solid-state overload relay, CLAS

MPN3RB2016-1SD0

Siemens SIRIUS solid-state overload relay, 3RB2016-1SD0, CLASS 10E, 3 poles, 45 mm width, ATEX Ex II (2) GD, contactor mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RB2016-1SD0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationsolid-state overload relay
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RB2016-1SD0 — Protection & Trip
ParameterValue
Overload current setting range3 ... 12 A
Trip classCLASS 10E
3RB2016-1SD0 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)0.05 W
Per pole0.02 W
3RB2016-1SD0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A
Switching current at 24 V2 A
Switching current at 60 V0.55 A
Switching current at 110 V0.3 A
Switching current at 120 V4 A
Switching current at 125 V0.3 A
Switching current at 220 V0.11 A
Switching current at 230 V3 A
3RB2016-1SD0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalYes
Conductor cross-section: solid2x (0.25 ... 1.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range (AWG), main contacts2x (18 ... 14)
Conductor range (AWG), auxiliary contacts2x (24 ... 16)
3RB2016-1SD0 — Environmental
ParameterValue
Operating temperature-25 ... +60 °C
Storage temperature-40 ... +80 °C
Transport temperature-40 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance15g / 11 ms
3RB2016-1SD0 — Mechanical
ParameterValue
Width45 mm
Height64 mm
Depth73 mm
3RB2016-1SD0 — Specifications
ParameterValue
Type Of ProtectionPTB 06 ATEX 3001 Ex II (2) GD

Product details

The Siemens SIRIUS 3RB2016-1SD0 is a solid-state overload relay rated for CLASS 10E tripping. Three poles for the main current circuit, 45 mm wide, mounting directly onto a contactor. Main circuit terminals are screw-type (2× 0.25…1.5 mm² solid or 2× 18…14 AWG), auxiliary and control circuit terminals are spring-loaded (2× 0.25…1.5 mm² or 2× 24…16 AWG). The spring-clamp on the aux side saves wiring time in the panel — no screwdriver torque check needed. ATEX approval is listed: PTB 06 ATEX 3001 Ex II (2) GD.

Fastening method is contactor mounting — the relay snaps onto the front of a SIRIUS contactor. Dimensions: 73 mm deep, 45 mm wide, 64 mm high. The 0 mm clearances upwards, forwards, and backwards. Side clearance of 6 mm required. Shock resistance rated at 15g / 11 ms — fine for most industrial machinery, but if you're on a vibrating conveyor or press, check the contactor's own shock spec too.

Environmental & EMC

Operating temperature range -25…+60 °C, storage and transport -40…+80 °C. Relative humidity during operation up to 100% — condensing environment is allowed, but the enclosure must still be rated for the location. Surge voltage resistance rated at 6 kV; burst immunity per IEC 61000-4-4 at 2 kV on power ports and 1 kV on signal ports, severity level 3. That covers most industrial panel transients from contactor coils and drives.

Switching capacity (auxiliary contacts)

The relay has zero CO (changeover) auxiliary contacts built in — the number of CO contacts for auxiliary contacts is listed as 0. That means all signaling (trip alarm, manual reset) must come from an external auxiliary contact block or from the contactor's own aux. The rated switching capacities at various voltages are provided: at 24 V it handles 2 A, at 120 V 4 A, at 230 V 3 A, and at lower DC voltages (60 V, 110 V, 125 V, 220 V) the currents are 0.55 A, 0.3 A, 0.3 A, 0.11 A respectively. These values apply to the auxiliary circuit (spring-loaded terminals) — use them for selecting the interface to a PLC input or a pilot lamp.

MPN
3RB2016-1SD0