Siemens 3RB2133-4QD0 — Overload Relays

Siemens 3RB2133-4QD0 SIRIUS Solid-State Overload Relay, 3-Po

MPN3RB2133-4QD0

Siemens SIRIUS solid-state overload relay, 3RB2133-4QD0, 3-pole, adjustable trip class 5E/10E/20E/30E, screw-type main terminals, spring-loaded aux terminals, ATEX Ex II (2) GD, contactor mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RB2133-4QD0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationsolid-state overload relay
Combinable contactor sizesS2
Reference code (IEC 81346-2)F
3RB2133-4QD0 — Protection & Trip
ParameterValue
Overload current setting range6 ... 25 A
Trip classCLASS 5E, 10E, 20E and 30E adjustable
3RB2133-4QD0 — Electrical (main circuit)
ParameterValue
Poles (main circuit)3
Rated insulation voltage (AC, pollution degree 3)690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)0.05 W
Per pole0.02 W
3RB2133-4QD0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gL/gG: 6 A
Switching current at 24 V2 A
Switching current at 60 V0.55 A
Switching current at 110 V0.3 A
Switching current at 120 V4 A
Switching current at 125 V0.3 A
Switching current at 220 V0.11 A
Switching current at 230 V3 A
3RB2133-4QD0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalYes
Conductor cross-section: solid2x (0.25 ... 1.5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.25 ... 1.5 mm²)
Conductor range (AWG), main contacts2 x (max. 4), 1 x (18 ... 2)
Conductor range (AWG), auxiliary contacts2x (24 ... 16)
3RB2133-4QD0 — Environmental
ParameterValue
Operating temperature-25 ... +60 °C
Storage temperature-40 ... +80 °C
Transport temperature-40 ... +80 °C
Relative humidity, operating100 %
Max. installation altitude2 000 m
Shock resistance15g / 11 ms
3RB2133-4QD0 — Mechanical
ParameterValue
Width55 mm
Height92 mm
Depth109 mm
3RB2133-4QD0 — Specifications
ParameterValue
Type Of ProtectionPTB 06 ATEX 3001 Ex II (2) GD

Product details

The Siemens 3RB2133-4QD0 is a SIRIUS solid-state overload relay — three-pole, designed to bolt directly onto a contactor (contactor mounting,) and protect motor circuits from sustained overcurrent without the mechanical fatigue of a bimetal strip. The trip class is adjustable across 5E, 10E, 20E, and 30E, so you dial in the protection curve that matches your motor's start-up profile: fast for short-stall pumps, slower for high-inertia loads like centrifuges or conveyors. Main power terminals are screw-type, rated for 1 x 18–2 AWG or 2 x 4 AWG max, and accept stranded up to 35 mm² — solid enough for a 50–60 A motor circuit. Auxiliary and control connections use spring-loaded terminals, which is the faster termination method for a panel builder wiring signal loops.

Environment and Compliance

This overload relay carries PTB 06 ATEX 3001 Ex II (2) GD certification, meaning it's approved for mounting in the non-hazardous area of a gas/dust zone — the associated apparatus that can sit outside the Ex zone while protecting motors inside it. It shrugs off 15g / 11 ms shock and 100 % relative humidity during operation — no special derating needed for a washdown environment as long as the enclosure is rated. Surge voltage resistance is 6 kV, and burst immunity meets IEC 61000-4-4 severity 3: 2 kV on power ports, 1 kV on signal ports. That's the level you want if the panel shares a cabinet with contactors or VFDs. Lifecycle status is current — this is a catalog-active part, not a phase-out risk.

Fastening method is contactor mounting — it clips directly onto the matching SIRIUS contactor, no DIN rail required. Mounting position is any orientation. The relay body is 55 mm wide, 92 mm tall, 109 mm deep. That zero-clearance top/bottom means it stacks tight in a multi-motor lineup — no air gap needed between relay and contactor above or below. Solid conductors: 2x (0.25... 1.5 mm²) for the aux circuit; finely stranded with ferrule the same. Stranded main conductors: 2x max 25 mm² or single 1–35 mm².

The built-in auxiliary contact set (spring-loaded terminals, 2x 24–16 AWG,) is rated for switching at several common control voltages: 2 A at 24 V, 0.55 A at 60 V, 0.3 A at 110 V, 4 A at 120 V, 0.3 A at 125 V, 0.11 A at 220 V, and 3 A at 230 V.

Frequently asked questions

What trip classes can the 3RB2133-4QD0 be set to?

Trip class is adjustable to CLASS 5E, 10E, 20E, or 30E — you set the protection curve to match the motor's start-up time.

Does the 3RB2133-4QD0 have ATEX certification?

Yes, it carries PTB 06 ATEX 3001 Ex II (2) GD, approved as associated apparatus for non-hazardous-area mounting protecting motors in gas/dust zones.

What are the main terminal wire sizes for 3RB2133-4QD0?

Screw-type main terminals accept 1 x 18–2 AWG or 2 x 4 AWG max, and stranded up to 1–35 mm² single or 2x 25 mm² max.

Where can I buy 3RB2133-4QD0 and how is it quoted?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

MPN
3RB2133-4QD0