Skip to main content
Siemens 3RB3016-1NB0 — Overload Relays

Siemens 3RB3016-1NB0 SIRIUS Solid-State Overload Relay, S00,

MPN3RB3016-1NB0
Active

Siemens SIRIUS solid-state overload relay, size S00, CLASS 10E, 690 V rated, 1.25 A thermal current, screw terminals, contactor mounting, 3RB3016-1NB0.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RB3016-1NB0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationsolid-state overload relay
Frame size (overload relay)S00
Combinable contactor sizesS00
Reference code (IEC 81346-2)F
3RB3016-1NB0 — Protection & Trip
ParameterValue
Overload current setting range0.32 ... 1.25 A
Trip classCLASS 10E
Overload release typeelectronic
3RB3016-1NB0 — Electrical (main circuit)
ParameterValue
Rated operational current1.25 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitscrew-type terminals
Power loss at rated current (hot)0.1 W
Per pole0.03 W
3RB3016-1NB0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A
Switching current at 24 V2 A
Switching current at 60 V0.55 A
Switching current at 110 V0.3 A
Switching current at 120 V4 A
Switching current at 125 V0.3 A
Switching current at 220 V0.11 A
Switching current at 230 V3 A
3RB3016-1NB0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typescrew-type terminals
Removable aux./control terminalYes
Conductor cross-section: solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
Conductor cross-section: solid or stranded1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²)
Conductor cross-section: finely stranded with ferrule1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Conductor range (AWG), auxiliary contacts1x (20 ... 14), 2x (20 ... 14)
3RB3016-1NB0 — Environmental
ParameterValue
Operating temperature-25 ... +60 °C
Storage temperature-40 ... +80 °C
Transport temperature-40 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
Shock resistance15g / 11 ms
3RB3016-1NB0 — Mechanical
ParameterValue
Width45 mm
Height79 mm
Depth73 mm

Product details

The Siemens 3RB3016-1NB0 is a SIRIUS solid-state overload relay in size S00, designed for motor protection in control panels.

Mounting and integration — fits a contactor, not a DIN rail alone

This relay mounts directly onto a contactor (fastening method: contactor mounting), not as a standalone DIN-rail device. Size S00 means it pairs with S00-frame contactors in the SIRIUS family. The 45 mm width and 79 mm height keep the footprint compact for dense panel layouts. Screw-type terminals for the main circuit accept 1x (0.5 to 4 mm²) solid or 2x (0.5 to 2.5 mm²) stranded — Pozidriv PZ 2 screwdriver tip, shaft diameter 5 to 6 mm.

Signaling contact ratings — what the tripped output can drive

The integrated signaling contact (the auxiliary switch that changes state on a trip event) is rated for switching various control voltages: 2 A at 24 V, 4 A at 120 V, 3 A at 230 V, and derated at higher DC voltages — 0.55 A at 60 V, 0.3 A at 125 V, 0.11 A at 220 V. These are the contact ratings for the "tripped" message output, not the main motor circuit. The per-pole power dissipation is 0.03 W, negligible for panel heat budgeting.

Storage and transport range is -40 to +80 °C. Shock resistance is 15g / 11 ms (signaling contact in tripped position: 9g / 11 ms per IEC 60068-2-27). Vibration resistance: 1-6 Hz at 15 mm amplitude, 6-500 Hz at 20 m/s², 10 cycles. Substance prohibitance date (RoHS-like) is 10/01/2009 — the part complies with the EU RoHS directive effective from that date.

Frequently asked questions

What is the tripped message output on this relay?

The part is noted "for message 'tripped'" — meaning the integrated auxiliary switch (signaling contact) changes state to indicate an overload trip condition. Its contact ratings are listed for various control voltages.

What are the key ratings of 3RB3016-1NB0?

CLASS 10E trip curve, rated insulation voltage 690 V, thermal current 1.25 A, size S00, electronic overload release, screw terminals, contactor mounting.

Where can I buy 3RB3016-1NB0 and get current pricing?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
3RB3016-1NB0