Skip to main content
Siemens 3RB3026-1RE0 — Overload Relays

Siemens 3RB3026-1RE0 SIRIUS solid-state overload relay, Clas

MPN3RB3026-1RE0
Active

Siemens SIRIUS solid-state overload relay, 3RB3026-1RE0, Size S0, 0.4 A thermal current, Trip Class 10E, spring-loaded terminals, contactor-mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RB3026-1RE0 — Identification
ParameterValue
Product brand nameSIRIUS
Product designationsolid-state overload relay
Frame size (overload relay)S0
Combinable contactor sizesS0
Reference code (IEC 81346-2)F
3RB3026-1RE0 — Protection & Trip
ParameterValue
Overload current setting range0.1 ... 0.4 A
Trip classCLASS 10E
Overload release typeelectronic
3RB3026-1RE0 — Electrical (main circuit)
ParameterValue
Rated operational current0.4 A
Poles (main circuit)3
Rated operating frequency50 ... 60 Hz
Rated insulation voltage (AC, pollution degree 3)690 V
Rated value (AC-3e), max.690 V
Rated surge withstand voltage6 kV
Main current circuitspring-loaded terminals
Power loss at rated current (hot)0.1 W
Per pole0.03 W
3RB3026-1RE0 — Auxiliary contacts
ParameterValue
Auxiliary contacts: NO1
Auxiliary contacts: NC1
Auxiliary contacts: CO (changeover)0
Auxiliary switch short-circuit protection (required fuse)fuse gG: 6 A
Switching current at 24 V2 A
Switching current at 60 V0.55 A
Switching current at 110 V0.3 A
Switching current at 120 V4 A
Switching current at 125 V0.3 A
Switching current at 220 V0.11 A
Switching current at 230 V3 A
3RB3026-1RE0 — Connection & Mounting
ParameterValue
Mounting / fastening methodContactor mounting
Mounting positionany
Main-circuit connector arrangementTop and bottom
Auxiliary/control circuit connection typespring-loaded terminals
Removable aux./control terminalYes
Conductor cross-section: solid2x (0.25 ... 1.5 mm²)
Conductor cross-section: solid or stranded2x (0,25 ... 1,5 mm²)
Conductor cross-section: finely stranded with ferrule2x (0.25 ... 1.5 mm²)
3RB3026-1RE0 — Environmental
ParameterValue
Operating temperature-25 ... +60 °C
Storage temperature-40 ... +80 °C
Transport temperature-40 ... +80 °C
Relative humidity, operating10 ... 95 %
Max. installation altitude2 000 m
Shock resistance15g / 11 ms
3RB3026-1RE0 — Mechanical
ParameterValue
Width45 mm
Height109 mm
Depth85 mm

Product details

The Siemens 3RB3026-1RE0 is a SIRIUS solid-state overload relay in Size S0, rated for a thermal current of 0.4 A at up to 690 V. Spring-loaded terminals on the main circuit accept 1× 10 mm² stranded or 2× 0.25–1.5 mm² solid/stranded — no screw torque checks, just strip and insert. Mounting is direct onto a contactor, any orientation. The 45 mm width and 85 mm depth keep panel layout tight — it tucks into a Size S0 starter assembly without stealing extra DIN rail.

The integrated auxiliary switch on the 3RB3026-1RE0 signals the tripped state via a dedicated contact. Its switching capacity varies with voltage: 2 A at 24 V, 4 A at 120 V, 3 A at 230 V, and 0.11 A at 220 V DC. At 24 V DC it easily drives a PLC digital input or a relay coil; at higher AC voltages the 3–4 A rating handles panel indication lamps or contactor hold-in circuits without an interposing relay. The note "for message 'tripped'" confirms this contact changes state only when the overload has operated — it's not a status mirror of the load current. Use it for a fault annunciator or to cut power to the drive enable, not for load monitoring.

The 3RB3026-1RE0 carries a lifecycle stage of "current" — Siemens still lists it as an active catalog number. No end-of-life or last-time-buy notice is on record.

Deployment context

This relay mounts directly onto a contactor rather than a DIN rail, so it stays with the starter assembly. The spring-loaded terminals and any-position mounting simplify panel wiring — no need to orient the relay for gravity drain or terminal access. Shock-rated to 15g / 11 ms and vibration-tested per 1–6 Hz / 15 mm and 6–500 Hz / 20 m/s², it holds up in applications near punch presses or conveyor drives.

Frequently asked questions

What is 3RB3026-1RE0's listed note (for message "tripped") on this component line?

The note indicates the integrated auxiliary contact is dedicated to signaling the tripped state — it closes or opens only when the overload relay has operated, not for load monitoring.

What is 3RB3026-1RE0's listed depth (85 mm) on this component line?

The depth is 85 mm, which together with the 45 mm width and 109 mm height fits the S0 contactor-mount footprint.

Will 3RB3026-1RE0 drop into a panel that was specified around 3RU2116-1FC1 without rewiring?

The 3RB3026-1RE0 and 3RU2116-1FC1 are different families — the 3RB is a solid-state electronic relay, while the 3RU is a bimetallic thermal relay. Both mount to Size S0 contactors, so the mechanical fit is the same, but the wiring (spring-loaded vs screw terminals) and the trip characteristic (electronic vs bimetal) differ. Verify the control circuit voltage and the auxiliary contact configuration before swapping.

MPN
3RB3026-1RE0