Skip to main content
Siemens 3RE4121-5BA35-4SH3 — Solid State Relays

Siemens 3RE4121-5BA35-4SH3

MPN3RE4121-5BA35-4SH3

Non-reversing motor starter, Frame size 00, Three phase full voltage, UL horsepower rating Hp@VAC, 1.5@208, 2@230, 3@460, 5@575, Solid-state overload relay, Selectable Trip Cl 5-10-20-30, OLR amp range 3 - 12, 110/120 V AC 50/60Hz coil, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use, Extra wide enclosure, Standards: UL 60947-4-1, Certifications: cULus, Including modifications: 22 mm Hand-Off-Auto Sel. Sw., Control power transformer

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RE4121-5BA35-4SH3 — Identification
ParameterValue
Product designationNon-reversing motor starter

Electrical

3RE4121-5BA35-4SH3 — Electrical
ParameterValue
Rated voltage, AC 60 Hz120 V
Rated voltage, AC 50 Hz110 V
Rated value at 200/208 V (hp)1.5 hp
Rated value at 220/230 V (hp)2 hp
Rated value at 460/480 V (hp)3 hp
Rated value at 575/600 V (hp)5 hp
Design Of The Short-Circuit TripThermal magnetic circuit breaker

Contacts & Poles

3RE4121-5BA35-4SH3 — Contacts & Poles
ParameterValue
Main circuit poles3
Main NO contacts (count)3
Auxiliary NO contacts (count)1
Auxiliary NC contacts (count)0
Auxiliary contacts, max. total6
Overload relay auxiliary NC contacts (count)1

Coil

3RE4121-5BA35-4SH3 — Coil
ParameterValue
Control supply voltage typeAC
Coil operating range factor (× rated)0.8 ... 1.1
Coil pick-up power, AC (apparent)26.4 VA
Coil holding power, AC (apparent)4.4 VA

Timing

3RE4121-5BA35-4SH3 — Timing
ParameterValue
ON-delay time9 ... 35 ms
OFF-delay time3.5 ... 14 ms

Approvals & Protection

3RE4121-5BA35-4SH3 — Approvals & Protection
ParameterValue
Overload protectionYes
Reset functionManual, automatic and remote
External resetYes
Test functionYes
Auxiliary contact rating, contactor (UL)10A@600V(A600), 2.5A@600V(Q600)
Auxiliary contact rating, overload relay (UL)5A@600VAC (B600), 1A@250VDC (R300)
Required short-circuit protection fuseClass J
Touch protection against electrical shockNA for enclosed products

Environmental

3RE4121-5BA35-4SH3 — Environmental
ParameterValue
Enclosure NEMA ratingNEMA 1 large size enclosure
Housing design / suitabilityindoors, usable on a general basis
Max. installation altitude6 560 ft
Max. permissible conductor temp, supply60 °C
Max. permissible conductor temp, load-side feeder60 °C
Max. permissible conductor temp, coil75 °C
Max. permissible conductor temp, auxiliary contacts (contactor)75 °C

Connection & Mechanical

3RE4121-5BA35-4SH3 — Connection & Mechanical
ParameterValue
Dimensions (H × W × D)14 × 8 × 7 in
Mounting positionVertical
Fastening / mounting methodSurface mounting and installation
Line-side terminal connection typeScrew-type terminals
Load-side terminal connection typeScrew-type terminals
Coil terminal connection typeScrew-type terminals
Connectable conductor, line-side (AWG)2x (20 ... 16), 2x (18 ... 14), 2x 12
Connectable conductor, load-side feeder (AWG)2x (20 ... 16), 2x (18 ... 14), 2x 12
Connectable conductor, coil (AWG)2x (20 ... 16), 2x (18 ... 14), 2x 12
Supply terminal tightening torque7 ... 10 lbf·in
Conductor material, supplyCU
Conductor material, load-side feederCU
Conductor material, coilCU
Conductor material, auxiliary contacts (contactor)CU
Conductor material, auxiliary contacts (overload relay)CU

Specifications

3RE4121-5BA35-4SH3 — Specifications
ParameterValue
Trip ClassCLASS 5 / 10 / 20 / 30
MPN
3RE4121-5BA35-4SH3