Skip to main content
Siemens 3RE4122-8CA11-4EB0 — Solid State Relays

Siemens 3RE4122-8CA11-4EB0 Motor Starter

MPN3RE4122-8CA11-4EB0

Non-reversing motor starter, Frame size 0, Three phase full voltage, UL horsepower rating Hp@VAC, 10@208, 10@230, 25@460, 25@575, Bimetal overload relay, Fixed Trip Class 10, OLR amp range 27 - 32, 24 V AC 50/60HZ coil, Non-combination type, Enclosure type 3/3R/4/12, Water/dust tight for outdoors, Standard width enclosure, Standards: UL 60947-4-1, Certifications: cULus With modifications: 22 mm Start-Stop push buttons

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jun 2026
How we verify every order →

Specifications

Identification

3RE4122-8CA11-4EB0 — Identification
ParameterValue
Product designationNon-reversing motor starter

Electrical

3RE4122-8CA11-4EB0 — Electrical
ParameterValue
Rated voltage, AC 60 Hz24 V
Rated voltage, AC 50 Hz24 V
Rated value at 200/208 V (hp)10 hp
Rated value at 220/230 V (hp)10 hp
Rated value at 460/480 V (hp)25 hp
Rated value at 575/600 V (hp)25 hp
Operating voltage for main current circuit at AC at 60 Hz maximum600 V
Design Of The Short-Circuit TripThermal magnetic circuit breaker

Contacts & Poles

3RE4122-8CA11-4EB0 — Contacts & Poles
ParameterValue
Main circuit poles3
Main NO contacts (count)3
Auxiliary NO contacts (count)1
Auxiliary NC contacts (count)1
Auxiliary contacts, max. total8
Overload relay auxiliary NC contacts (count)1

Coil

3RE4122-8CA11-4EB0 — Coil
ParameterValue
Control supply voltage typeAC
Coil operating range factor (× rated)0.8 ... 1.1
Coil pick-up power, AC (apparent)79 VA
Coil holding power, AC (apparent)8.5 VA

Timing

3RE4122-8CA11-4EB0 — Timing
ParameterValue
ON-delay time8 ... 40 ms
OFF-delay time4 ... 16 ms

Approvals & Protection

3RE4122-8CA11-4EB0 — Approvals & Protection
ParameterValue
Overload protectionYes
Reset functionManual, automatic and remote (with optional accessory)
External resetYes
Test functionYes
Auxiliary contact rating, contactor (UL)10A@600V(A600), 2.5A@600V(Q600)
Auxiliary contact rating, overload relay (UL)5A@600VAC (B600), 1A@250VDC (R300)
Required short-circuit protection fuseClass J
Touch protection against electrical shockNA for enclosed products

Environmental

3RE4122-8CA11-4EB0 — Environmental
ParameterValue
Enclosure NEMA ratingNEMA 3/3R/4/12 enclosure
Housing design / suitabilityDust- & watertight for outdoor use
Max. installation altitude6 560 ft
Max. permissible conductor temp, supply60 °C
Max. permissible conductor temp, load-side feeder60 °C
Max. permissible conductor temp, coil75 °C
Max. permissible conductor temp, auxiliary contacts (contactor)75 °C

Connection & Mechanical

3RE4122-8CA11-4EB0 — Connection & Mechanical
ParameterValue
Dimensions (H × W × D)12 × 10 × 6 in
Mounting positionvertical
Fastening / mounting methodSurface mounting and installation
Line-side terminal connection typeScrew-type terminals
Load-side terminal connection typeScrew-type terminals
Coil terminal connection typeScrew-type terminals
Connectable conductor, line-side (AWG)2x (16 ... 12), 2x (14 ... 8)
Connectable conductor, load-side feeder (AWG)2x (16 ... 12), 2x (14 ... 8)
Connectable conductor, coil (AWG)2x (16 ... 12), 2x (14 ... 8)
Supply terminal tightening torque18 ... 21 lbf·in
Conductor material, supplyCU
Conductor material, load-side feederCU
Conductor material, coilCU
Conductor material, auxiliary contacts (contactor)CU
Conductor material, auxiliary contacts (overload relay)CU
MPN
3RE4122-8CA11-4EB0