Siemens 3RG9001-0AB00 — Digital Output Modules

Siemens 3RG9001-0AB00 Digital Output Module, 4 Relay Outputs

MPN3RG9001-0AB00
End of Life

Siemens 3RG9001-0AB00, AS-Interface digital output module, 4 relay outputs, IP67, 27mm depth, 45mm width, 90mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RG9001-0AB00 — Outputs
ParameterValue
Digital outputs4
3RG9001-0AB00 — Identification
ParameterValue
Type4 outputs
3RG9001-0AB00 — Mechanical & Connection
ParameterValue
Width45mm
Height90mm
Depth27mm

Product details

EOL hot — 4 relay outputs, IP67 field module

The Siemens 3RG9001-0AB00 is an AS-Interface digital output module with 4 relay outputs, housed in an IP67-rated enclosure for direct field mounting without a control cabinet. The relay outputs switch DC loads up to 1 A (DC-13 at 24 V) or 0.5 A (DC-13 at 24 V) depending on the load type, with a total aggregate current of 2 A across all outputs.

External 24V AUX required — relay hold state on comms loss

The module requires an external auxiliary power supply (AUX POWER) of 20 to 30 V DC, compliant with VDE 0106 (PELV), protection class III, to energize the output circuits. This supply connects via an M12 connector. During a communication failure on the AS-Interface bus, the relay outputs remain in their current switching state — no drop-out, no default. This behavior is critical for fail-safe applications where outputs must hold position rather than revert to a safe-off state.

Mounting and connectivity — DIN rail or wall, M12 screw terminals

The I/O connections use M12 screw-type terminals (4 sockets for outputs D0–D3), with contact pins on the FK or Pg coupling module for the AS-Interface bus. Dimensions: 27 mm depth, 45 mm width, 90 mm height. The IP67 rating means the module withstands washdown environments — suitable for food-and-bev or wet-area deployment without an enclosure.

Frequently asked questions

Does the Siemens 3RG9001-0AB00 need an external auxiliary power supply?

Yes, an external 20–30 V DC AUX supply is required for the output circuits. The supply must meet VDE 0106 (PELV), protection class III, and connects via an M12 connector.

What happens to the outputs during a communication failure?

The relay outputs remain in their current switching state — they do not change until communication is restored. This is a hold-state behavior, not a safe-off default.

What is the pinout of the Siemens 3RG9001-0AB00 module?

The module has 4 M12 sockets for outputs D0 through D3. The AS-Interface bus connection uses contact pins on the FK or Pg coupling module. A detailed pinout diagram is in the product datasheet.

MPN
3RG9001-0AB00