Skip to main content
Siemens 3RH1122-1AB00-ZW96 — Contactors

Siemens 3RH1122-1AB00-ZW96 SIRIUS Auxiliary Contactor, Size

MPN3RH1122-1AB00-ZW96

Siemens SIRIUS auxiliary contactor, size S00, 2 NO + 2 NC, 10 A at 24 V, 45 mm wide, screw and snap-on mounting, IP20 front protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1122-1AB00-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RH1122-1AB00-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1122-1AB00-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RH1122-1AB00-ZW96 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1122-1AB00-ZW96 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1122-1AB00-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1122-1AB00-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1122-1AB00-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RH1122-1AB00-ZW96 is a SIRIUS auxiliary contactor in size S00, with 2 NO and 2 NC contacts rated at 10 A at 24 V, surge voltage resistance of 6 kV, 45 mm width, and screw and snap-on mounting.

The 10 A at 24 V rating is the continuous thermal current (Ith) for the auxiliary contacts — it's not a motor-switching figure. For inductive loads at higher voltages, the switching capacity drops: at 230 V it's rated 6 A, at 400 V it's 3 A, and at 690 V it's 1 A. The 2 NO + 2 NC contact configuration is the standard complement for a feedback or interlock circuit on a contactor or soft starter.

Screw terminals accept 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², or 2x 4 mm² solid conductors.

Frequently asked questions

Does the 3RH1122-1AB00-ZW96 drop into a panel specified for a 3RT1015-1AG61?

Both are size S00 devices with the same 45 mm width and screw/snap-on mounting, so the auxiliary contactor fits the same DIN-rail or screw-mounting footprint. The wiring terminals accept the same conductor ranges. The difference is function: the 3RT1015 is a power contactor for motor loads, while this is an auxiliary block for control circuits.

MPN
3RH1122-1AB00-ZW96