Siemens 3RH1122-1AT60 — Contactors

Siemens SIRIUS 3RH1122-1AT60 Auxiliary Contactor, Size S00

MPN3RH1122-1AT60

Siemens SIRIUS auxiliary contactor, Size S00, 3RH1122-1AT60, 2 NO + 2 NC, 10 A AC-12, 45 mm width, screw and snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1122-1AT60 — Identification
ParameterValue
Contactor frame sizeS00
3RH1122-1AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1122-1AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RH1122-1AT60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1122-1AT60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1122-1AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1122-1AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1122-1AT60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries 2 normally-open and 2 normally-closed instantaneous contacts, all rated for AC-12 duty at 10 A maximum, which means they switch resistive control loads like relay coils and indicator lamps within a panel. The Size S00 frame keeps the footprint tight at 45 mm wide by 57.5 mm tall by 72 mm deep, so it slots into a crowded DIN-rail enclosure without eating up rows.

Mounting and wiring — panel fit

Wire terminals accept solid conductors from 0.5 mm² up to 4 mm² (two per clamp), or AWG 20–12 for the stranded equivalent.

The headline 10 A AC-12 rating governs resistive control loads. For inductive loads the current drops: 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, and 1 A at 690 V. At 24 V DC the contact carries 10 A, but at 110 V DC it falls to 1 A and at 220 V DC to 0.27 A — so if you're switching a DC solenoid bank at higher voltage, watch the derating curve. The contact reliability spec (one incorrect operation per 100 million at 17 V, 1 mA) means it handles dry logic-level signals without needing a separate interface relay, which is useful when a PLC output drives a long cable run to the contactor.

Frequently asked questions

What wire sizes does 3RH1122-1AT60 accept?

Each screw terminal accepts two solid conductors in the ranges 0.5–1.5 mm², 0.75–2.5 mm², or one 4 mm² conductor. For AWG, two 20–16, two 18–14, or one 12 AWG.

Where can I buy 3RH1122-1AT60?

This part is sourced to order; availability and pricing are confirmed at quote time.