Siemens 3RH1122-2AB00-0TK1 — Contactors

Siemens 3RH1122-2AB00-0TK1 SIRIUS Auxiliary Contactor, 2 NO

MPN3RH1122-2AB00-0TK1

Siemens SIRIUS, auxiliary contactor, 3RH1122-2AB00-0TK1, size S00, 2 NO instantaneous contacts, screw and snap-on mounting, IP20 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1122-2AB00-0TK1 — Identification
ParameterValue
Contactor frame sizeS00
3RH1122-2AB00-0TK1 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1122-2AB00-0TK1 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RH1122-2AB00-0TK1 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1122-2AB00-0TK1 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1122-2AB00-0TK1 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1122-2AB00-0TK1 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1122-2AB00-0TK1 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The Siemens 3RH1122-2AB00-0TK1 is a SIRIUS auxiliary contactor in size S00, carrying 2 normally-open instantaneous contacts. It is designed to switch control signals and auxiliary loads in motor starter and contactor assemblies — the kind of signal-level switching that governs a contactor coil or a PLC input in a panel.

The 2 NO contacts are rated for switching at various control voltages: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. The contacts are instantaneous (no make-before-break or delayed action), so they close and open with the main contactor armature. This makes the 3RH1122-2AB00-0TK1 suitable for switching PLC-level DC signals without the contact wetting issues common on standard power contactors. This aligns with requirements for industrial control panels.

RoHS compliance date is noted as July 1, 2006, which aligns with the EU RoHS directive effective date. The product extension for auxiliary switches is marked as Yes, so add-on blocks are available if the 2 NO contacts are insufficient.

Dimensions are 45 mm wide, 60 mm high, and 73 mm deep — the S00 footprint that fits standard contactor/relay spacing on DIN rail. The solid conductor capacity is 2x (0.25 to 2.5 mm²), which covers the common control wiring range from signal-level twisted pair to 14 AWG power-limited circuits. Terminal screws accept both solid and stranded wire within that range. Shock resistance is 10g at 5 ms and 5g at 10 ms — adequate for most industrial machinery but not rated for continuous high-G environments like engine test cells without additional damping.

Frequently asked questions

What is the physical size and mounting method?

It measures 45 mm wide, 60 mm high, and 73 mm deep, fitting the S00 frame size. Mounting is via screw or snap-on onto DIN rail, with flexible orientation options including +/-180° rotation and +/-22.5° tilt.

MPN
3RH1122-2AB00-0TK1