Skip to main content
Siemens 3RH1122-2AP60 — Contactors

Siemens 3RH1122-2AP60 SIRIUS Auxiliary Contactor, 2 NO, Size

MPN3RH1122-2AP60

Siemens SIRIUS auxiliary contactor, size S00, 2 NO instantaneous contacts, screw and snap-on mounting, IP20 front, 73 mm depth, 45 mm width, 60 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1122-2AP60 — Identification
ParameterValue
Contactor frame sizeS00
3RH1122-2AP60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1122-2AP60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RH1122-2AP60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1122-2AP60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1122-2AP60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1122-2AP60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1122-2AP60 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The 3RH1122-2AP60's contacts are rated for 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V — covering the typical control-voltage range from 24 VDC up to 690 VAC. At 110 V the rating drops to 1 A, and at 220 V it is 0.27 A. These are the thermal current ratings; the actual switching capacity depends on the load type and duty cycle, but the 6 kV surge voltage resistance and pollution degree 3 indicate the contactor is built for industrial environments with transient overvoltages and conductive contamination.

Mechanical endurance and reliability

Shock resistance is 10g / 5 ms and 5g / 10 ms, adequate for panel-mounted equipment in most industrial machinery.

Mounting and environmental specs

Accepts solid conductors of 2x 0.25 to 2.5 mm². The 73 mm depth, 45 mm width, and 60 mm height fit the standard S00 footprint, so it occupies the same panel space as other SIRIUS S00 contactors and auxiliary blocks.

Frequently asked questions

What is the contact configuration of 3RH1122-2AP60?

It has two normally-open (NO) instantaneous contacts. There are no normally-closed, delayed, lagging, or make-before-break contacts on this variant.

What are the rated contact currents at different voltages?

At 24 V it is rated 10 A; at 230 V, 6 A; at 400 V, 3 A; at 690 V, 1 A. At 110 V the rating is 1 A, and at 220 V it is 0.27 A.

What is the mechanical life of 3RH1122-2AP60?

Typical mechanical endurance is 30 million operating cycles. Contact reliability is specified as one incorrect switching operation per 100 million operations at 17 V, 1 mA.

Where can I buy 3RH1122-2AP60?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN