It carries two instantaneous normally open contacts and two normally closed contacts, rated for AC-12 switching up to 10 A at 24 V, with a 30 V DC coil rated at 3.2 W holding power.
Environmental and electrical ratings
Shock resistance is 10g for 5 ms and 5g for 10 ms — enough for most industrial cabinets but not for direct mounting on a vibrating machine base. Pollution degree 3 means it handles conductive dust and condensation typical in control rooms and light industrial environments. The coil draws 3.2 W DC both during pick-up and hold, so no inrush spike to stress the control transformer.