Siemens 3RH1122-2BM40 — Contactors

Siemens 3RH1122-2BM40 SIRIUS Auxiliary Contactor, Size S00,

MPN3RH1122-2BM40

Siemens SIRIUS auxiliary contactor, size S00, 2 normally open instantaneous contacts, screw and snap-on mounting, IP20, rated 10 A at 24 V / 6 A at 230 V, depth 73 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1122-2BM40 — Identification
ParameterValue
Contactor frame sizeS00
3RH1122-2BM40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1122-2BM40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RH1122-2BM40 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1122-2BM40 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1122-2BM40 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1122-2BM40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1122-2BM40 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

It provides two normally open instantaneous contacts, rated for 10 A at 24 V and 6 A at 230 V, with a surge voltage resistance of 6 kV. Rated for pollution degree 3, it suits environments with conductive contamination. This flexibility simplifies integration into existing panel layouts where space or orientation is constrained.

The 10 A rating at 24 V DC covers typical PLC digital output loads and relay coils. At 230 V AC the contactor handles 6 A, enough for small solenoid valves or indicator circuits. The 6 kV surge voltage rating means it withstands switching transients common in industrial environments without contact welding or insulation breakdown. Contact reliability is specified as one incorrect switching operation per 100 million cycles at 17 V and 1 mA — important for low-energy signal switching where oxide films on contacts can cause intermittent faults. The mechanical endurance of 30 million operations is typical for a SIRIUS auxiliary contactor in cyclic service. Wire termination accepts 2x (0.25 to 2.5 mm²) solid or stranded conductors.

The 3RH1122-2BM40 is the auxiliary contactor companion to Siemens SIRIUS contactors in size S00. If a panel was specified around a 3RT1015 contactor, this auxiliary contactor shares the same S00 footprint and mounting rail, so it drops in without rewiring the main power circuit. Verify the coil voltage of the main contactor separately — this listing is for the auxiliary block only.

At 45 mm wide, 60 mm tall, and 73 mm deep, this auxiliary contactor occupies a single 45 mm DIN-rail module. The depth of 73 mm means it clears most standard 80 mm deep enclosures, but check gland plate clearance if the panel is shallow. Shock resistance is 10g for 5 ms and 5g for 10 ms, covering most industrial vibration environments up to moderate shock.

Frequently asked questions

What is the depth of this auxiliary contactor?

The depth is 73 mm. Combined with a width of 45 mm and height of 60 mm, it fits a standard 45 mm DIN-rail footprint.

What wire sizes does the terminal accept?

It accepts 2x (0.25 to 2.5 mm²) solid conductors. For stranded wire, use ferrules within the same cross-section range.

Will this drop into a panel specified for a 3RT1015-1BB42 without rewiring?

The 3RH1122-2BM40 shares the same SIRIUS S00 footprint and DIN-rail mounting as the 3RT1015 series contactors. It will mount on the same rail and the auxiliary wiring terminals are in the standard positions, so no rewiring of the main power circuit is needed. Verify the coil voltage of the main contactor is compatible with your control voltage.

What compliance documentation is available?

The part carries a substance prohibition date of 01.07.2006, indicating RoHS compliance. The reference code per IEC 81346-2 is K (contactors/relays). For specific UL, CSA, or CE certificates, request the manufacturer's declaration with your RFQ.

MPN
3RH1122-2BM40