Siemens 3RH1131-1AB00-0TK1 — Contactors

Siemens 3RH1131-1AB00-0TK1 SIRIUS Auxiliary Contactor, 3 NO,

MPN3RH1131-1AB00-0TK1

Siemens SIRIUS auxiliary contactor, 3RH1131-1AB00-0TK1, Size S00, 3 NO instantaneous contacts, screw and snap-on mounting, IP20 front protection, 6 kV surge voltage resistance.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1131-1AB00-0TK1 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-1AB00-0TK1 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-1AB00-0TK1 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RH1131-1AB00-0TK1 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-1AB00-0TK1 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1131-1AB00-0TK1 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-1AB00-0TK1 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1131-1AB00-0TK1 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

Its three normally-open instantaneous contacts switch pilot loads, signal feedback, or interlock circuits.

Switching capacity varies with voltage: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, down to 1 A at 690 V. That's the load it can break across the contact gap — the 6 kV rated surge voltage means the contacts handle transient spikes common in inductive circuits without welding or arcing over. Contact reliability is specified at one incorrect switching operation per 100 million cycles at 17 V, 1 mA — that's the dry-circuit performance for low-energy signals like PLC inputs. Mechanical life of 30 million operations covers the typical panel lifetime.

Environmental tolerance — built for the nacelle or the panel

Shock resistance: 10g for 5 ms and 5g for 10 ms. That covers the vibration and thermal cycling inside a wind turbine nacelle or a conveyor line cabinet.

Solid wire terminals accept 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², and 2x 4 mm². That's two conductors per clamp — useful for daisy-chaining control voltage or looping feedback signals without extra terminal blocks. The IP20 front protection means the contactor is touch-safe on the front face once installed in an enclosure.

Frequently asked questions

Will 3RH1131-1AB00-0TK1 drop into a panel specified for 3RH2131-2AK60?

Both are Size S00 SIRIUS auxiliary contactors with the same mounting footprint (screw and snap-on, 45 mm width). The difference is contact configuration: this one has 3 NO contacts, while the 3RH2131-2AK60 carries a different contact arrangement. Check your circuit's NO/NC needs before substitution.