Siemens 3RH1131-1AC00-0TK2-ZX95 — Contactors

Siemens 3RH1131-1AC00-0TK2-ZX95 SIRIUS Auxiliary Contactor,

MPN3RH1131-1AC00-0TK2-ZX95

Siemens SIRIUS auxiliary contactor, 3RH1131-1AC00-0TK2-ZX95, 3 instantaneous NO contacts, size S00, screw and snap-on mounting, IP20 front, 45 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1131-1AC00-0TK2-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-1AC00-0TK2-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-1AC00-0TK2-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz32 V
3RH1131-1AC00-0TK2-ZX95 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-1AC00-0TK2-ZX95 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1131-1AC00-0TK2-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-1AC00-0TK2-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1131-1AC00-0TK2-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries 3 instantaneous normally-open contacts and is sized S00, meaning it mates directly with the S00 contactor family (e.g., 3RT1015, 3RT1016, 3RT1017) for mirroring or extending auxiliary contact sets on a DIN rail. At 45 mm wide and 72 mm deep, it occupies a single DIN-rail slot alongside its parent contactor. The screw and snap-on mounting lets you clip it onto the rail or onto the contactor's side without tools — common for panel builders wiring control circuits.

Pollution degree 3 means this contactor is rated for environments where conductive dust settles on the terminals — exactly what a cement plant control room sees. The IP20 front keeps fingers and tools out but does not seal against airborne grit; the enclosure around the panel provides that seal. Storage and transport range -55 to +80 °C means it survives a hot truck or warehouse without degrading. Shock resistance 10g / 5 ms and 5g / 10 ms is enough for normal machine vibration and handling drops. Contact reliability is rated at one incorrect switching operation per 100 million cycles at 17 V and 1 mA — that is the dry-circuit limit. For PLC-level signals (24 VDC, 10 A rated at 24 V), this contactor switches reliably without gold-plating.

Wiring and mounting notes

Terminals accept solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm². No leading or delayed switching action — all three contacts close simultaneously.

Frequently asked questions

Will this drop into a panel specified around a 3RT1015-1AG61 without rewiring?

The 3RH1131-1AC00-0TK2-ZX95 is size S00, the same frame as the 3RT1015 series. It mounts directly onto the side of the S00 contactor or on the DIN rail next to it. Terminal spacing and conductor ranges match the S00 footprint, so no rewiring of the control circuit is needed — just add the auxiliary block.

What is the depth of this auxiliary contactor?

72 mm.

What conductor sizes does the terminal accept?

Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm².

MPN
3RH1131-1AC00-0TK2-ZX95