Siemens 3RH1131-1AF10-ZX95 — Contactors

Siemens SIRIUS 3RH1131-1AF10-ZX95 Auxiliary Contactor, 10 A

MPN3RH1131-1AF10-ZX95

Siemens SIRIUS auxiliary contactor, type 3RH1131-1AF10-ZX95, 3 NO + 1 NC, size S00, 10 A AC-12, 45 mm width, screw and snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1131-1AF10-ZX95 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-1AF10-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-1AF10-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz230 V
3RH1131-1AF10-ZX95 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-1AF10-ZX95 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1131-1AF10-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-1AF10-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1131-1AF10-ZX95 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

It carries 3 normally-open and 1 normally-closed instantaneous contacts, rated 10 A in AC-12 duty (resistive loads at 24 V), with a rated surge voltage resistance of 6 kV. The AC-12 rating governs its use for switching resistive loads in control circuits — think PLC outputs, relay coils, or indicator lamps — not motor starting. The 10 A figure at 24 V is the continuous thermal current; derate for higher voltages per the switching capacity curve (1 A at 110 V, 0.27 A at 220 V).

The S00 frame measures 45 mm wide by 57.5 mm deep by 72 mm tall — a compact footprint that fits standard DIN-rail enclosures. Fastening is via screw or snap-on mounting; the snap-on option allows tool-less rail attachment, useful during panel assembly. Wire termination accepts solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or 2x 4 mm² per terminal. For AWG: 2x (20...16), 2x (18...14), or 1x 12.

Environmental and reliability specs

Shock resistance is rated at 10g for 5 ms and 5g for 10 ms. The mechanical endurance is 30 million operations typical.

Frequently asked questions

What compliance documentation is available for this part?

RoHS compliance is confirmed with a substance prohibition date of July 1, 2006. The part is designed to meet IEC/EN standards for industrial control equipment. Certification documentation (declaration of conformity, RoHS report) is available through the authorized Siemens distributor chain.

What is the depth of this auxiliary contactor?

The depth is 72 mm. Combined with a width of 45 mm and height of 57.5 mm, this S00 frame fits standard DIN-rail enclosures and leaves room for adjacent devices in a dense panel layout.

What wire sizes does the terminal accept?

Solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), or 2x 4 mm² per clamp. AWG equivalents: 2x (20...16), 2x (18...14), or 1x 12. The spring-cage or screw terminals (depending on variant) accept ferruled stranded as well.

How does this compare to the 3RT1017-1AP01 contactor?

The 3RT1017-1AP01 is a main power contactor (size S00, 7 A AC-3 at 400 V) for switching motor loads. The 3RH1131-1AF10-ZX95 is an auxiliary contactor — it has no main power contacts and is designed to mirror the state of a main contactor or provide additional signal contacts. They share the same S00 frame and mounting footprint, so the auxiliary contactor can snap onto the main contactor or mount adjacent on the same DIN rail without rewiring the panel layout. The key difference: one switches motor current, the other switches control signals.

MPN
3RH1131-1AF10-ZX95