Skip to main content
Siemens 3RH1131-1AG60 — Contactors

Siemens 3RH1131-1AG60 SIRIUS Auxiliary Contactor, 10A AC-12,

MPN3RH1131-1AG60

Siemens SIRIUS auxiliary contactor, Size S00, 3RH1131-1AG60, 45 mm width, 10 A AC-12 rated, screw and snap-on mounting, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1131-1AG60 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-1AG60 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-1AG60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz100 V
3RH1131-1AG60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-1AG60 — Protection & Coordination
ParameterValue
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RH1131-1AG60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RH1131-1AG60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-1AG60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH1131-1AG60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

What this SIRIUS auxiliary contactor delivers on the line

AC-12 rated at 10 A — that's the resistive load curve for control circuits, so it holds takt time on auxiliary contact switching without derating for typical PLC or relay coil loads. Three instantaneous contacts (NO/NC configurable) give you the flexibility to mirror status back to the controller or interlock downstream contactors without adding a separate relay bank. Mechanical life is spec'd at 30,000,000 operations typical — that's the kind of endurance you want when the line cycles every few seconds. Mounts via screw or snap-on to DIN rail, and the 45 mm width keeps the panel density tight.

Mounting and integration — checklist items

Screw and snap-on mounting onto standard DIN rail. Depth is 72 mm, width 45 mm, height 57.5 mm. Solid terminal capacity accepts 2x conductors from 0.5 to 1.5 mm², 2x from 0.75 to 2.5 mm², or 2x up to 4 mm² — spring-cage or screw terminals depending on variant; this unit supports both stranded and solid wire with ferrule. Pollution degree 3 (conductive pollution, typical for industrial panels) so no additional conformal coating needed for most environments. Shock resistance at 10g / 5 ms and 5g / 10 ms keeps it reliable on vibrating conveyor sections or press lines.

For compliance documentation: as a Siemens SIRIUS component, it meets CE, UL, CSA, and CCC requirements per the manufacturer's declarations. RoHS and REACH compliance is standard for this generation of SIRIUS hardware. Specific cert numbers are on the nameplate; we can provide the manufacturer's declaration of conformity with your order if your quality doc control requires it.

What the AC-12 rating means for your control circuit

The 10 A at AC-12 rating is the key figure for control engineers. AC-12 per IEC 60947-5-1 covers resistive loads and solid-state outputs — think PLC digital outputs, relay coils, solenoid valves, and indicator lamps. That 10 A is the maximum thermal current (Ith) for the contact block; it's not a motor-switching number. For inductive DC loads at 24 V, the rating drops to 10 A as well, but at 110 V DC it's 1 A, and at 220 V DC it's 0.27 A — so if you're switching DC solenoids at higher voltages, check the voltage-specific curve. AC-15 and DC-13 ratings (typical for solenoid and electromagnetic loads) are not listed in this spec set — if your circuit drives highly inductive loads like contactor coils without suppression, verify the switching capacity against the load's inrush. The 3 instantaneous contacts handle make/break simultaneously; there are no leading, lagging, or make-before-break contacts on this variant.

Frequently asked questions

How do I get current pricing and availability for 3RH1131-1AG60?

Submit an RFQ for this order code. Pricing and availability are confirmed at quote time; we source the part through independent distribution channels and can provide a firm quote with current lead time on request.

What is the closest functional second-source to 3RH1131-1AG60?

The 3RH2131-2AK60 is a Size S00 auxiliary contactor from the same SIRIUS family, but it carries 2 normally open and 2 normally closed contacts (4-pole) versus the 3-pole configuration of the 3RH1131-1AG60. It also has a different coil voltage and terminal arrangement — verify the contact configuration and wiring diagram before substituting. The 3RH1131-1AG60 is the 3-pole, 1 NO + 2 NC (or configurable) variant.

What is the depth of 3RH1131-1AG60?

72 mm depth, 45 mm width, 57.5 mm height. Fits standard Size S00 DIN-rail footprint.

What wire sizes does 3RH1131-1AG60 accept?

Solid terminals accept 2x conductors from 0.5 to 1.5 mm², 2x from 0.75 to 2.5 mm², or 2x up to 4 mm². Suitable for solid and stranded wire with ferrule.

Will 3RH1131-1AG60 drop into a panel specified for 3RH2131-2AK60 without rewiring?

Not without checking the contact configuration. The 3RH1131-1AG60 has 3 instantaneous contacts (configurable NO/NC), while the 3RH2131-2AK60 has 4 contacts (2 NO + 2 NC). Both are Size S00 with the same 45 mm width and DIN-rail mounting, so the mechanical footprint matches. But the terminal assignment and number of contact poles differ — review your schematic to confirm the contact count matches before swapping.

What compliance documentation does Siemens provide for 3RH1131-1AG60?

As a SIRIUS component, the 3RH1131-1AG60 carries CE, UL, CSA, and CCC approvals per Siemens' standard declarations. RoHS and REACH compliance documentation is available from the manufacturer. Specific certificate numbers are printed on the product nameplate.

MPN
3RH1131-1AG60