Siemens 3RH1131-1AT60 — Contactors

Siemens 3RH1131-1AT60 SIRIUS Auxiliary Contactor, 10 A AC-12

MPN3RH1131-1AT60

Siemens SIRIUS auxiliary contactor, size S00, 3RH1131-1AT60, 3 NO instantaneous contacts, 10 A AC-12, screw and snap-on mounting, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1131-1AT60 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-1AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-1AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RH1131-1AT60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-1AT60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1131-1AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-1AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1131-1AT60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth72 mm

Product details

The Siemens 3RH1131-1AT60 is a SIRIUS auxiliary contactor in size S00 — a compact 45 mm wide block that adds three normally open instantaneous contacts to a control circuit. It is not a main power contactor; it is the signal-side relay that extends the I/O of a larger contactor or feeds status back to a PLC. Rated 10 A in AC-12 duty (resistive loads at 24 V), it handles the typical control-voltage switching inside a panel — pilot lights, solenoid valves, PLC inputs. At 230 V the rating drops to 6 A, and at 400 V to 3 A, so the thermal curve governs the real load; do not size it by the 10 A headline alone. Contact reliability is specified as one incorrect switching operation per 100 million cycles at 17 V, 1 mA — that is the low-level signal performance an integrator needs when the contactor feeds a dry-contact input card.

Fastens by screw or snaps onto a DIN rail. Terminals accept solid conductors: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², or 2x 4 mm². AWG equivalents: 2x 20–16, 2x 18–14, or 1x 12. Spring-cage or screw terminals? The evidence does not specify the termination type — verify the physical sample if your panel standard requires a specific style.

Shock resistance: 10g / 5 ms and 5g / 10 ms. Surge voltage resistance rated at 6 kV. Substance prohibition date (RoHS-like) is 07/01/2006.