Siemens 3RH1131-2AG10 — Contactors

Siemens 3RH1131-2AG10 SIRIUS Auxiliary Contactor, 10 A AC-12

MPN3RH1131-2AG10

Siemens SIRIUS auxiliary contactor, 3RH1131-2AG10, S00 frame, 10 A AC-12, 45 mm width, screw and snap-on mounting, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RH1131-2AG10 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-2AG10 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-2AG10 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz100 V
3RH1131-2AG10 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-2AG10 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting
3RH1131-2AG10 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-2AG10 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH1131-2AG10 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

The Siemens 3RH1131-2AG10 is a SIRIUS auxiliary contactor in the S00 frame size, rated for 10 A at AC-12 duty — that's the resistive-load curve for control circuits, so it handles solenoid valves, contactor coils, and indicator lamps without derating. It carries 3 normally open instantaneous contacts and no delayed or leading/lagging switching, making it a straight-forward add-on for extending a contactor's auxiliary contact count or building a standalone interlock.

Mounts via screw or snap-on onto a DIN rail; the 45 mm width and 73 mm depth fit the standard S00 footprint, so it drops into any panel already laid out for that frame. The mounting position allows ±180° rotation on a vertical surface and ±22.5° tilt forward/backward — useful when you're squeezing it into a tight enclosure corner.

Ratings and environment

Rated surge voltage withstand is 6 kV, which covers most 400 V industrial control panels without additional suppression. IP20 on the front keeps fingers out but expects the panel enclosure to provide the washdown or dust seal. Operating temperature range is -25 to +60 °C; storage and transport go from -55 to +80 °C. Shock resistance is 10g for 5 ms and 5g for 10 ms — enough for most machine-mounted panels but not for high-vibration applications like a press or crusher without additional damping.

Wiring and contact reliability

Terminals accept 2x (0.25 to 2.5 mm²) solid or 2x (24 to 14 AWG) stranded — standard for control wiring. Contact reliability is specified as one incorrect switching operation per 100 million operations at 17 V, 1 mA, which is the low-level signal reliability spec; if you're switching dry contacts or PLC inputs, this contactor won't give you nuisance failures.

Frequently asked questions

How do I get current pricing and availability for 3RH1131-2AG10?

Submit an RFQ through this listing; availability and current pricing are confirmed at quote time through independent distribution channels.

What is the depth of 3RH1131-2AG10?

The depth is 73 mm, part of the standard S00 frame size that also carries a 45 mm width and 60 mm height.

What wire sizes does 3RH1131-2AG10 accept?

It accepts 2x (0.25 to 2.5 mm²) solid or 2x (24 to 14 AWG) stranded conductors per terminal.

Will 3RH1131-2AG10 drop into a panel specified around 3RH2131-2AK60 without rewiring?

Both are S00 frame auxiliary contactors with the same 45 mm width and screw/snap-on mounting, so the mechanical fit is identical. The 3RH2131-2AK60 carries different contact configurations and coil voltage — verify your circuit's contact count and coil rating before swapping.

What compliance documentation does Siemens provide for 3RH1131-2AG10?

The part carries RoHS compliance with a substance prohibition date of July 1, 2006, and is rated for pollution degree 3 and surge voltage 6 kV per IEC/EN 60947 standards.

MPN
3RH1131-2AG10