It carries 3 instantaneous normally-open contacts rated at 10 A at 24 V (AC-12 duty), and the coil pulls in on 24 V DC with a steady-state holding power of 3.2 W.
The 3 NO contacts are rated for AC-12 switching at 10 A maximum — that covers resistive control loads like relay coils and indicator lamps. For inductive loads at higher voltages, derate accordingly: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V. The coil is 24 V DC only; closing and holding both draw 3.2 W, so a standard 24 VDC power supply sized for the inrush handles it fine.
The 45 mm width and 60 mm height keep it compact for multi-contactor assemblies.